WASHINGTON, DC —
OSHA Inspection: BRUNO CLAY MANAGEMENT, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BRUNO CLAY MANAGEMENT, LLC in 200 RHODE ISLAND AVENUE, NE, WASHINGTON, DC 20001 (NAICS 236220). OSHA activity number 334850583.
Where did this inspection happen?
- Establishment
- BRUNO CLAY MANAGEMENT, LLC
- Site address
- 200 RHODE ISLAND AVENUE, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 11701 BOWMAN GREEN DRIVE, RESTON, VA 20190
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1101 K02 II
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
9954
General-duty citation text
29 CFR 1926.1101(k)(2)(ii): Building and/or facility owners did not notify the following persons of the presence, location and quantity of ACM or PACM, at the work sites in their buildings and facilities. (a) On or about May 21, 2012, in the West Garage, Bruno Clay, the building Owner's authorized representative, did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, prior to them putting up temporary lighting by tying it to electrical pipes in the ceiling area that contained pipes with damaged, friable, thermal system insulation that contained 30 percent Chrysotile asbestos, of the location and quantity of ACM or PACM in the area. The workers were exposed to the hazards associated with asbestos. (b) On or about May 21, 2012, in the West Garage, Bruno Clay, the building Owner's authorized representative, did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, prior to them splicing wire in the electrical conduit boxes located above the garage doors near a ceiling that contained pipes with damaged, friable, thermal system insulation that contained 30 percent Chrysotile asbestos, of the location and quantity of ACM or PACM in the area. The workers were exposed to the hazards associated with asbestos. (c) On or about May 21, 2012, in the East Garage, Bruno Clay, the building Owner's authorized representative, did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, prior to them trouble shooting the electrical boxes located near pipes with damaged, friable, thermal system insulation that contained 25 to 70 percent Chrysotile, of the location and quantity of ACM or PACM in the area. The workers were exposed to the hazards associated with asbestos.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1101 K02 II A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
9954
General-duty citation text
29 CFR 1926.1101(k)(2)(ii)(A): Building and/or facility owners failed to notify prospective employers applying for or bidding for work whose employees can reasonably be expected to work in or adjacent to areas containing asbestos containing material or presumed asbestos containing material of the presence, location and quantity: (a) On or about May 21, 2012, in the West Garage, Bruno Clay, the building Owner's authorized representative, did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, of the location and quantity of ACM or PACM in the area. The workers were exposed to the hazards associated with asbestos. (b) On or about May 21, 2012, in the East Garage, Bruno Clay, the building Owner's authorized representative did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, of the location and quantity of ACM or PACM in the area. The workers were exposed to the hazards associated with asbestos.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 K08 VII
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
9954
General-duty citation text
29 CFR 1926.1101(k)(8)(vii): After the building owner or employer identified previously installed presumed asbestos containing material (PACM) and/or asbestos containing material (ACM), labels or signs were not affixed or posted so that employees would be notified of what materials contain PACM and/or ACM, and/or the employer did not post signs in lieu of labels, and/or ensure, to the extent feasible, that employees who come in contact with these signs or labels could comprehend them: (a) On or about May 21, 2012, in the West Garage, Bruno Clay, the building Owner's authorized representative, did not post signs at the entrance into the area prior to RE Newcomb Electric, their Electrical Contractor, putting up temporary lighting and splicing wire in electrical conduit boxes. The workers were exposed to the hazards associated with asbestos. (b) On or about May 21, 2012, in the East Garage, Bruno Clay, the building Owner's authorized representative, did not identify the presence, location, and quantity of ACM/PACM, and did not inform RE Newcomb Electric, their Electrical Contractor, prior to them trouble shooting electrical boxes. The workers were exposed to the hazards associated with asbestos.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections at BRUNO CLAY MANAGEMENT, LLC
WASHINGTON, DC—2019-01-07 00:00:00
BRUNO CLAY MANAGEMENT LLC
View BRUNO CLAY MANAGEMENT, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334850583.