BOULDER CITY, NV ·
OSHA Inspection: DEPARTMENT OF THE INTERIOR, BUREAU OF RECLAMATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEPARTMENT OF THE INTERIOR, BUREAU OF RECLAMATION in 500 FIR STREET, BLDG 1100, BOULDER CITY, NV 89005 (NAICS 924120). OSHA activity number 334867199.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEPARTMENT OF THE INTERIOR, BUREAU OF RECLAMATION
- Site address
- 500 FIR STREET, BLDG 1100
- City
- BOULDER CITY
- State
- NV
- ZIP
- 89005
- Mailing
- 500 FIR STREET, BOULDER CITY, NV 89005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 850
- Ownership type
- Federal government (D)
Citations
5 citations on file for this inspection.
1910.157 C01
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable Fire Extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) Bureau Of Reclamation, Fish Lab Building 1100, a portable fire extinguisher was observed lying flat on the work bench next to FL 13 duplex convenience outlet.
Recent events (1)
- · Z (S) $0
1910.165 E
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.165(e): Manually operated actuation devices for use in conjunction with employee alarms were not unobstructed, conspicuous and readily accessible: (a) Bureau of Reclamation, Fish Lab Building 1100, the FCI, FL-7 manually operated actuation fire alarm device was obstructed by a Super G3 copy machine.
Recent events (1)
- · Z (S) $0
1910.253 B02 II
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. (a) Bureau of Reclamation, Fish Lab Building 1100, nitrogen compressed gas cylinders were not properly secured; a bungy cord was used to hold the cylinders in place.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. (a) Bureau of Reclamation, Fish Lab Building 1100, a stolberg relocatable power tap was permanently mounted to on the cubicle and the other relocatable power tap was connected to a yellow extension cord.
Recent events (1)
- · Z (S) $0
1910.303 G01
- Issued
- Sep 18, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment. (a) Bureau of Reclamation, Fish Lab Building 1100, a general duty safety switch and an electrical power panel were blocked by a 175 psi compressor and a Gary Fisher bicycle.
Recent events (1)
- · Z (S) $0
More inspections at Department of the Interior, Bureau of Reclamation
View Department of the Interior, Bureau of Reclamation's full OSHA safety record →