OSHA Inspection: HP MANUFACTURING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HP MANUFACTURING in 3705 CARNEGIE AVE., CLEVELAND, OH 44115 (NAICS 326199). OSHA activity number 334884988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HP Manufacturing — free Get an email when a new federal OSHA severe-injury report for HP Manufacturing is published. One employer, no account, unsubscribe in one click.
Establishment
HP MANUFACTURING
Site address
3705 CARNEGIE AVE.
City
CLEVELAND
State
OH
ZIP
44115
Mailing
3705 CARNEGIE AVE., CLEVELAND, OH 44115
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
92
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 92 exposed
Issued
Dec 3, 2012
Abate by
Jan 5, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:          Although the employer developed and implemented an energy control program for use at the facility, it was deficient and did not include specific machine procedures, which are used to identify applicable energy sources and the appropriate methods for isolating, blocking, or securing machinery. Equipment includes, but is not limited to; the companys (2) stand mounted routing machines and (3) CNC machines.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C07 I A

Serious Gravity 5 5 instances 92 exposed
Issued
Dec 3, 2012
Abate by
Dec 20, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:     On and before 06/26/2012 employees authorized to perform lockout/tagout at the site were not trained in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available at the site, and the methods and means necessary for energy isolation. Equipment includes, but is not limited to; (2) stand mounted routers and (3) CNC milling centers.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.212 A03 II

Serious Gravity 10 2 instances 92 exposed
Issued
Dec 3, 2012
Abate by
Dec 20, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or before 06/26/2012 the following equipment, located in the machine shop area, was not equipped with point of operation guarding.  The unguarded equipment includes:      a. (2) stand mounted routers;     b. (3) Haas CNC Milling Centers. The access door interlocks were bypassed.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.303 B02

Serious Gravity 5 2 instances 92 exposed
Issued
Dec 3, 2012
Abate by
Dec 20, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      The following electrical equipment was not installed in accordance with instructions included in the listing or labeling:    a. The metal junction box, located in the machine shop- production area was not installed in a neat workmanlike       manner.  The  box was not mounted to a fixed surface nor connected to the conduit.     b. The switch used for turning on and off routing machinery, was a standard household light switch, and is not designed       to prevent unintentional restarting of the machinery and/or constructed and mounted to minimize inadvertent       operation.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.132 D01

Other-than-serious 1 instance 92 exposed
Issued
Dec 3, 2012
Abate by
Jan 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    On or before 06/26/2012 a workplace hazard assessment was not completed by the employer.  Personal protective equipment such as, but not limited to, safety eyewear, protective gloves or a face shield may be necessary for employees tasked with changing out the propane cylinder on the company's fork truck.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View HP Manufacturing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334884988.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.