CLEVELAND, OH —
OSHA Inspection: HP MANUFACTURING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HP MANUFACTURING in 3705 CARNEGIE AVE., CLEVELAND, OH 44115 (NAICS 326199). OSHA activity number 340899871.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HP MANUFACTURING
- Site address
- 3705 CARNEGIE AVE.
- City
- CLEVELAND
- State
- OH
- ZIP
- 44115
- Mailing
- 3705 CARNEGIE AVE., CLEVELAND, OH 44115
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 55
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 II
- Issued
- Nov 12, 2015
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On and before September 9, 2015, the employer had not performed lockout tagout periodic inspections for machinery such as but not limited to the CNC Onsrud router.
Recent events (2)
- — I (S) $1000
- — Z (S) $3500
1910.147 D04 I
- Issued
- Nov 12, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On September 1, 2015, the employer did not ensure employees performing mechanical servicing to the misaligned sensor for the Onsrud plastic product router locked out the equipment.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.303 G02 I
- Issued
- Nov 12, 2015
- Penalty
- Initial $3,500 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On September 9, 2015, the electrical circuit breaker box above the work bench at the Onsrud plastic product router was open and had two overcurrent device openings exposing live electrical parts.
Recent events (2)
- — I (S) $2500
- — Z (S) $3500
1910.37 B02
- Issued
- Nov 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On September 9, 2015, the southwest exit discharge doorway was not marked as an exit.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at HP Manufacturing
View HP Manufacturing's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340899871.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.