GREENVILLE, PA ·
OSHA Inspection: DECLAN CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DECLAN CONSTRUCTION, INC. in 75 COLLEGE AVENUE THIEL COLLEGE SCIENCE BUILDING, GREENVILLE, PA 16125 (NAICS 236220). OSHA activity number 334907789.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DECLAN CONSTRUCTION, INC.
- Site address
- 75 COLLEGE AVENUE THIEL COLLEGE SCIENCE BUILDING
- City
- GREENVILLE
- State
- PA
- ZIP
- 16125
- Mailing
- 7013 WARREN SHARON ROAD, BROOKFIELD, OH 44403
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.303 B01
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $1,440 · Current $2,160
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of American National Standards Institute, B7.1-1970, Safety Code for the Use, Care and Protection of Abrasive Wheels, and paragraph (d) of this section: A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: An employee was utilizing a DeWalt 4 1/2" angle grinder (M/N: DW402 / A/N: D129897) to grind metal during demolition operations. The angle grinder was not equipped with a guard.
Recent events (2)
- · I (S) $2160
- · Z (S) $1440
1926.404 B01 I
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $2,160 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: Employees utilizing extension cords, relocatable power tap, and a DeWalt 4 1/2" Angle Grinder (M/N: DW402 / A/N: D129897) that were not protected by a GFCI or AEGP.
Recent events (2)
- · I (S) $0
- · Z (S) $2160
1926.403 B02
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: An employee was utilizing a Curtis SP-700 relocatable power tap to supply power to a DeWalt 4 1/2" angle grinder (M/N: DW402 / A/N: D129897) and a DeWalt DW9116 1-hour NiCd Charger. The power tap was not listed/labeled for use in a construction site work environment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.405 A02 II I
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: A flexible extension cord which was ultimately supplying power to a DeWalt 4 1/2" angle grinder (M/N: DW402 / A/N: D129897) and a DeWalt DW9116 1-hour NiCd Charger was laying in shards of glass which exposed the cord to damage.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B01
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: Employees were performing demolition work on the roof of a structure. Employees were exposed to a fall hazard of at least 25-feet. Employees were not utilizing and/or protected by any fall protection systems.
Recent events (2)
- · I (S) $2520
- · Z (S) $2520
1926.453 B02 V
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: An employee was not utilizing fall protection devices while in the basket of the Genie S-60X aerial lift. Personnel were exposed to a fall hazard of at least 25-feet while operating the aerial lift.
Recent events (2)
- · I (S) $0
- · Z (S) $1800
1926.503 B01
- Issued
- Aug 22, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. A.) Declan Construction, Inc., 75 College Avenue, Greenville, PA 16125, Thiel College, Science Building, on or about June 26, 2012 and times prior thereto: Employee was working on the roof of a structure and exposed to a fall hazard greater than 6-feet. Employee's fall protection training was not properly certified in writing.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Declan Construction, INC.
View Declan Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334907789.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.