Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: DECLAN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DECLAN CONSTRUCTION, INC. in 894 DIAMOND PARK, MEADVILLE, PA 16335 (NAICS 236220). OSHA activity number 334942984.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Declan Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Declan Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
894 DIAMOND PARK
City
MEADVILLE
State
PA
ZIP
16335
Mailing
7013 WARREN SHARON ROAD, BROOKFIELD, OH 44403
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
Private (A)

1 citation on file for this inspection.

1926.501 B14

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 10, 2012
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1926.501(b)(14):     Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.    a)  construction site, 894 Diamond Park in Meadville, PA, rear of building.  On or about June 28, 2012, employees were exposed to falls, 10 feet to the lower level, while walking/working near the unprotected, open doorway. Fall protection systems were not utilized to guard and/or protect personnel from the fall hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1800

View Declan Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334942984.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.