OSHA Inspection: BENJI'S STORM PROTECTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENJI'S STORM PROTECTION in 19-2-149-12, ST THOMAS, VI 00803 (NAICS 238110). OSHA activity number 334953783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benji'S Storm Protection — free Get an email when a new federal OSHA severe-injury report for Benji'S Storm Protection is published. One employer, no account, unsubscribe in one click.
Site address
19-2-149-12
City
ST THOMAS
State
VI
ZIP
00803
Mailing
P.O. BOX 306016, ST THOMAS, VI 00803
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(b)(1)(i):     Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform):    On or about 06/25/12, at 19-2-149-12 Smith Bay, St Thomas, VI, employees were observed working from a scaffold that was not fully planked.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $1360

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(e)(1):     When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    On or about 06/25/12, at 19-2-149-12 Smith Bay, St Thomas, VI, employees were observed working from a scaffold that was not equipped with a ladder or any other means of access to and from the scaffold.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $1360

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about 06/25/12, at 19-2-149-12 Smith Bay, St Thomas, VI, employees were using a ladder to access the third level working platform of a scaffold, the side rails did not extend at least 3 feet above the landing surface.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4):     Ladders shall be used only for the purpose for which they were designed:    On or about 06/25/12, at 19-2-149-12 Smith Bay, St Thomas, VI, employees were using a astepladder as a non-self-supporting ladder to access a scaffold.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.451(g)(1)(vii):     For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    On or about 06/25/12, at 19-2-149-12 Smith Bay, St Thomas, VI, employees were observed working from a scaffold that was not equipped with a guardrail system or any other type of fall protection system to protect the employees from falls.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.