ST THOMAS, VI —
OSHA Inspection: BENJI'S STORM PROTECTION
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of BENJI'S STORM PROTECTION in NAZARETH, ST THOMAS, VI 00802 (NAICS 238110). OSHA activity number 346856099.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BENJI'S STORM PROTECTION
- Site address
- NAZARETH
- City
- ST THOMAS
- State
- VI
- ZIP
- 00802
- Mailing
- P.O. BOX 306016, ST THOMAS, VI 00803
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 A01
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $2,678 · Current $2,678
General-duty citation text
29 CFR 1926.451(a)(1):Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a) On or about 7/24/2023, an employee was working on a wooden scaffold built by 2x4x3/4" boards that could not withstand 4 times the weight that was applied to it.
Recent events (1)
- — Z (S) $2678
1926.451 B01 II
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $2,678 · Current $2,678
General-duty citation text
29 CFR 1926.451(b)(1)(ii):Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm). a) On or about 7/24/2023, an employee was working on a wooden scaffold that was not planked fully planked, leading to a very thin working area.
Recent events (1)
- — Z (S) $2678
1926.451 C02
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $4,465 · Current $4,465
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) On or about 7/24/2023, an employee was working on a scaffold that did not have mud sills, base plates, or any form of firm foundation to prevent the scaffold from sinking into the ground.
Recent events (1)
- — Z (S) $4465
1926.451 G01 VII
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $2,678 · Current $2,678
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. On or about 7/24/2023, Nazareth #9-55, Charlotte Amalie VI 00802 - an employee was working from a wooden scaffold that was not equipped with a guardrail system or any other type of fall protection system to protect the employees from a fall hazard. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (1)
- — Z (S) $2678
1926.701 B
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $3,572 · Current $3,572
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement. (a) On or about 7/25/2023, Nazareth #9-55, Charlotte Amalie VI 00802 - all protruding reinforced steel did not have rebar caps, exposing employees to impalement hazards. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (1)
- — Z (S) $3572
1926.25 B
- Issued
- Sep 15, 2023
- Abate by
- Sep 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.25(b):Combustible scrap and debris shall be removed at regular intervals during the course of construction. Safe means shall be provided to facilitate such removal. a) On or about 7/25/2023, employees were working with large amounts of combustible wood in multiple piles inside and surrounding the building.
Recent events (1)
- — Z (O) $0
More inspections at Benji'S Storm Protection
View Benji'S Storm Protection's full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in VI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346856099.