APPLING, GA ·
OSHA Inspection: B & J CUSTOM CABINETS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of B & J CUSTOM CABINETS, INC. in 5839 COBBHAM ROAD, APPLING, GA 30802 (NAICS 337110). OSHA activity number 335021382.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B & J CUSTOM CABINETS, INC.
- Site address
- 5839 COBBHAM ROAD
- City
- APPLING
- State
- GA
- ZIP
- 30802
- Mailing
- 5839 COBBHAM ROAD, APPLING, GA 30802
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 5
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.107 C04
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(c)(4): Wiring conformance. Electrical wiring and equipment did not conform to the provisions of this paragraph and were not otherwise be in accordance with subpart S of this part. B & J Custom Cabinets, Inc. - on or about July 5, 2012, wiring in a spray area was not rated for the operation. Outlets and conduit were not intrinsically safe for the operation. Area used for application of flammable wood finish, paint, stains.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.107 D05
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(5): Electric motor(s) driving exhaust fan(s) for spray booth(s) were located inside the booth(s): B & J Custom Cabinets, Inc. - on or about July 5, 2012, spray application of flammable wood finish, paint, and stain was performed in a designated spray area, which included a fan drawing vapors to the exterior of the building. The motor of the fan was inside the spray area, where it could be exposed to flammable vapors.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 E02
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations exceeded minimum required for operations and ordinarily exceeded a supply for 1 day or one shift: B & J Custom Cabinets, Inc. - on or about July 5, 2012, flammable liquids were stored inside the spray room, rather than in a separate araea away from the spray operation. The amount present was over 40 gallons, and more than that used in a single shift. Products stored in area included paints and stains.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.134 C01
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: B & J Custom Cabinets, Inc. - on or about July 5, 2012, employees were required to wear filtering facepiece respirators when sanding wood cabinets, and a half-face air purifying respirator when spraying. The employer did not develop and implement a written Respiratory Protection program. 1. In the main production area, employees are required to wear filtering facepiece respirators when sanding unfinished products, several times per week. 2. In the spray area, the painter uses an air-purifying half-face respirator when applying paint and stains. Spraying is done approximately two hours per day.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 E01
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: B & J Custom Cabinets, Inc. - on or about July 5, 2012, employees were required to wear respirators. The employer had not performed medical evaluations to determine the employees's ability to safely use respirators. 1. In the main production area, employees wear filtering facepiece respirators when operating orbital and belt sanders. 2. In the spray area, the employee wears a half-face air-purifying respirator when applying wood finish, paint, and stains.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 F01
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): B & J Custom Cabinets, Inc. - on or about July 5, 2012, employees wear respirators but have not received fit tests to ensure proper wearing/use and protection from airborne contaminants. 1. In the main production area, employees are required to wear filtering facepieces when using orbital and belt sanders. 2. In the spray area, the employee is required to wear a half-face air-purifying respirator when applying wood finish, paint, and stains.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): B & J Custom Cabinets, Inc. - on or about July 5, 2012, an employee worked with wood finish and stain products that contained flammable and otherwise hazardous ingredients. Employer did not develop and implement a written Hazard Communication program.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 G01
- Issued
- Sep 25, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: B & J Custom Cabinets, Inc. - on or about July 5, 2012, employees used wood finish, paint, and stain in production of wood cabinets. Products present fire and inhalation hazards, but the employer could not readily produce the MSDS.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at B & J Custom Cabinets, INC.
View B & J Custom Cabinets, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335021382.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.