On , OSHA opened a referral safety inspection of RODNEY HUNT COMPANY INC. in 46 MILL ST., ORANGE, MA 01364 (NAICS 332312). OSHA activity number 335152781.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RODNEY HUNT COMPANY INC.
- Site address
- 46 MILL ST.
- City
- ORANGE
- State
- MA
- ZIP
- 01364
- Mailing
- 46 MILL ST., ORANGE, MA 01364
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 280
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.37 A03
- Issued
- Sep 20, 2012
- Penalty
- Initial $2,550 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Rodney Hunt Company, Exit by laser cutting machine; The egress route by the laser cutting machine in the manufacturing building was blocked by equipment on two seperate days. Instance 1: The exit route was blocked by a large container used to collect scrap metal on July 11, 2012. Instance 2: The exit route was blocked by multiple pallets and other equipment on August 20, 2012.
Recent events (2)
- — I (S) $2000
- — Z (S) $2550
1910.178 Q07
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $2,550 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service, or were placed in service if the examination showed conditions adversely affecting the safety of the vehicle. Shipping area, The Rodney Hunt Company; The powered industrial truck used in the shipping area, Model GP060RDNUAF086, SN N473349, was not examined and placed in service with a broken windshield that partially blocked or distorted the view of the driver.
Recent events (2)
- — I (O) $2000
- — Z (S) $2550
1910.212 A03 IV E
- Issued
- Sep 20, 2012
- Penalty
- Initial $4,250 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(e): Employee(s) were using milling machines without point of operation guarding in place. Milling machine adjacent to supervisor's office, Rodney Hunt Company, Orange, MA: An employee was using the milling machine with the attached guard pulled out of the way exposing the employee to point of operation hazards and struck by hazards from flying debris.
Recent events (2)
- — I (S) $3000
- — Z (S) $4250
1910.215 A04
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $2,550 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Delta 8 inch bench grinder, Milling area, adjacent to Supervisor's Office, Rodney Hunt Company: The work rests of the Delta 8 inch bench grinder were not adjusted to a maximum of one eighth inch from the wheel. Using a wooden carpenter measure, the gap was found to be approximately one quarter inch on the left wheel and three eighths inch on the right wheel.
Recent events (2)
- — I (S) $2000
- — Z (S) $2550
1910.215 B09
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Delta eight inch bench grinder, adjacent to the Supervisor's Office in the manufacturing area; The tongue guards on the Delta eight inch bench grinder were not adjusted to within a quarter inch from the wheel with the tongue guard on the right wheel adjusted to approximately nine sixteenth of an inch from the wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Metal racks at laser cutter, manufacturing building, The Rodney Hunt Company; The chains and sprockets used to drive and support the shelves on the metal racks for the laser cutting machine were not fully enclosed to protect employees from in-running nip points.
Recent events (2)
- — I (S) $0
- — Z (S) $3400
1910.332 B03
- Issued
- Sep 20, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $7,000 · Current $5,000 Reduced
8870
General-duty citation text
29 CFR 1910.332(b)(3): Employees were not trained in and familiar with the safety related work practices required by 29 CFR 1910.331 through 29 CFR 1910.335 that pertained to their respective job assignments: The Rodney Hunt Company, Orange, MA; Employees who perform electrical maintenance and repairs have not been provided with electrical safe work practice training sufficient to be aware of the hazards of working in the vicinity of energized equipment or the precautions to take to protect themselves from those hazards.
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.333 B02
- Issued
- Sep 20, 2012
- Abate by
- Nov 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): The Rodney Hunt Company, Orange, MA; The Rodney Hunt Company lockout program does not address electrical lockout requirements as required by 29 CFR 1910.333(b)(2) including but not limited to verifying deenergization by a qualified person using test equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Manufacturing building, Laser Cutting Machine and welding area, Rodney Hunt Company; Employees were not visually inspecting flexible cord sets for damage prior to use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: Manufacturing building, multiple locations, Rodney Hunt Company, Orange, MA; The employer did not ensure that second use containers with cleaning solvent were labeled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rodney Hunt Company INC.
View Rodney Hunt Company INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335152781.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.