Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRANNON RECYCLING, L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRANNON RECYCLING, L.L.C. in 8861 US HIGHWAY 31, HANCEVILLE, AL 35077 (NAICS 423930). OSHA activity number 335203014.

Watch Brannon Recycling, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Brannon Recycling, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
8861 US HIGHWAY 31
City
HANCEVILLE
State
AL
ZIP
35077
Mailing
8861 US HIGHWAY 31, HANCEVILLE, AL 35077
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
6
Ownership type
A

9 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:      (a) On or about 07/13/2012 - Shop Area, cans were piled up to six feet high limiting employee access to and from the work area without climbing over the piles of cans.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.109 J04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1910.109(j)(4)(i): Small arms ammunition primers shall not be stored except in the original shipping container in accordance with the requirements of 49 CFR 173.107 for small arms ammunition primers:      (a) On or about 07/13/2012 - Shop Area, small arms ammunition primers stored in a 5-gallon bucket.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.219 C04 I

Serious Gravity 10 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:      (a) On or about 07/13/2012 - Shop Area,  the can machine crush roller motor was missing guards on projecting shafts without smooth ends and the shafts projected more than 1/2 the diameter of the shaft.    (b) On or about 07/13/2012 - Shop Area,  the can machine crush roller was missing guards on projecting shafts without smooth ends, had set screws exposed, and the shafts projected more than 1/2 diameter of the shaft .    (c) On or about 07/13/2012 - Shop area,  The can machine blower motor was missing guards on projecting shafts without smooth ends and the shafts projected more than 1/2 diameter of the shaft .    (d) On or about 07/13/2012 - Shop Area, the can machine incline conveyor was missing guards on projecting shafts without smooth ends and the shafts projected more than 1/2 diameter of the shaft .
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.219 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:       (a) On or about 07/13/2012 - Shop Area, Can Machine, sprocket wheels and chain on the incline conveyor were not guarded.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.252 A02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use:      (a) On or about 07/13/2012 - Shop Area, a fire extinguisher was blocked by materials.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.303 B01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:      (a) On or about 07/13/2012 - Shop Area, Can Machine, Conveyor Motor, the protective conduit was broken on a transfer motor exposing the insulated wires.    (b) On or about 07/13/2012 - Shop Area, Can Machine, Crusher Motor, the protective conduit was broken on the motor exposing the insulated wires.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.303 B02

Serious Gravity 5 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      (a) On or about 07/13/2012 - Shop Area, two shop-made extension cords hanging from the ceiling used to power scales and other equipment were made out of parts designed for permanent installation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.303 G02 I

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):      (a) On or about 07/13/2012 - Shop Area, a 220-volt electrical circuit breaker panel was missing the trim and deadfront exposing live electrical parts.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 G01

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      (a) On or about 07/13/2012 - Shop Area, a 220-volt electrical circuit breaker panel was blocked by materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BRANNON RECYCLING, L.L.C.'s full OSHA safety record →