Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: BRANNON RECYCLING, L.L.C.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRANNON RECYCLING, L.L.C. in 82065 US HIGHWAY 278, BLOUNTSVILLE, AL 35031 (NAICS 331492). OSHA activity number 337927024.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brannon Recycling, L.L.C. for free Get an email when a new federal OSHA severe-injury report for Brannon Recycling, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
82065 US HIGHWAY 278
City
BLOUNTSVILLE
State
AL
ZIP
35031
Mailing
8861 US HIGHWAY 31, HANCEVILLE, AL 35077
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
5
Ownership type
Private (A)

11 citations on file for this inspection.

1910.215 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):      (a)  On or about 12/18/13 - Non-ferrous Shop, the guards on the pedestal mounted abrasive grinder were not installed.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.215 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:      (a)  On or about 12/18/13 - Non-ferrous Shop, the work rest guards on the pedestal mounted abrasive grinder were not adjusted to at least one-eighth inch.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:      (a)  On or about 12/18/13 - Non-ferrous Shop, the tongue guards on the pedestal mounted abrasive grinder were not adjusted to at least one-fourth inch.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      (a)  On or about 12/18/13 - Weld Shop, a shop-made extension cord used to power grinders and other portable tools was made out of parts designed for permanent installation.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.305 G02 II

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:      (a) On or about 12/18/12 - Weld Shop, damaged extension cord(s) were spliced exposing conductors.    (b) On or about 12/18/12 - Non-ferrous Metal Shop, damaged extension cord(s) were spliced exposing conductors.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:      (a) On or about 12/18/12 - Can Machine, the protective conduit was broken on a transfer pump exposing the insulated wires.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.303 G02 I

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):      (a) On or about 12/18/12 - Outside the Weld Shop, the electrical panel for the weld shop building rated at 480 volts was missing the cover and dead front exposing live parts.    (b) On or about 12/18/12 - Storage Room in the Scale House Offices, the fuse box panel for the building rated at 220 volts was missing the cover and dead front exposing live parts.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.303 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      (a)  On or about 12/18/12 - Storage Room in the Scale House Offices, the fuse box panel for the building rated at 220 volts was blocked by boxes and material.
Recent events (1)
  • · Z (S) $0

1910.304 G05

Serious Gravity 5 3 instances 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      (a)  On or about 12/18/12 - Non-ferrous Room, an extension cord used to service the heater had the grounding prong missing.    (b)  On or about 12/18/12 - Non-ferrous Room, an extension cord used to service the bench grinder had the grounding prong missing.    (c)  On or about 12/18/12 - Weld Shop, an extension cord used to service hand grinders had the grounding prong missing.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.305 B02

Serious Gravity 5 3 instances 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:      (a)  On or about 12/18/12 - Scale House, three 110-volt branch circuit receptacles were missing the faceplates.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:      (a) On or about 12/18/12 - Weld Shop, a cover was missing on the 4 x 4 junction box.
Recent events (1)
  • · Z (S) $0

View Brannon Recycling, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 337927024.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.