BERNIE, MO —
OSHA Inspection: AMES TRUE TEMPER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMES TRUE TEMPER in 206 E. HUNT AVE., BERNIE, MO 63822 (NAICS 321999). OSHA activity number 335205985.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMES TRUE TEMPER
- Site address
- 206 E. HUNT AVE.
- City
- BERNIE
- State
- MO
- ZIP
- 63822
- Mailing
- P. O. BOX 700, BERNIE, MO 63822
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 40
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.95 I05
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors: a. Temporary employees were not provided initial fitting instruction; sound level meter readings indicated exposures from 91 to 97 dBA (the company had implemented a hearing conservation program for full time employees). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.95 I03
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer: a. Only one type of heairng protector was provided to employees; sound level meter readings indicated exposures up to 97 dBA. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 K01
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k): a. Temporary employees were not provided hearing conservation training; sound level meter readings indicated exposures from 91 to 97 dBA (the company had implemented a hearing conservation program for full time employees). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I B
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a. Temporary employees, who worked at the various woodworking machines, were not provided lockout/tagout training. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E06 II
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I liquids were dispensed into containers without the nozzle and container electrically interconnected: a. In the outside flammable storage building, where a flammable liquid (a primer) was dispensed from a 55 gal. drum into an approximate 1 gal. container, the drum and container were not electrically bonded. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.106 E07 I C
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(7)(i)(c): Where flammable vapor-air mixtures may exist under abnormal conditions (Class I, Division II), hazardous classified electrical wiring and equipment was not installed: a. In the outside flammable storage building, where a flammable liquid (a primer) was dispensed from a 55 gal. drum into an approximate 1 gal. container, Class I, Division II hazardous location electrical wiring and equipment was not installed, inlcuding a 110 V freezer next to the 55 gal. drum, and a duplex outlet. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Multiple examples existed of equipment being used without equipment grounding protection, including as a result of missing ground pins, missing equipment grounding conductor, or faulty equipment, such as in building 1, where a cooling fan power cord was misisng a ground pin. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.305 B02
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. A damaged 110 V duplex outlet was used to power equipment (in building 1 by the equalizer saw). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. At least one instance existed with no strain relief at a 110 V cooling fan power cord where it was attached to the motor terminal screws (building 2). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Jul 24, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a. The lockout procedures did not provide specific information such as, but not limited to, the specific location and device to be used to lockout equipment and the specific equipment to be used to verify lockout, such as for the injection molding machines. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ames True Temper
View Ames True Temper's full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335205985.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.