FORT HUACHUCA, AZ ·
OSHA Inspection: U.S. ARMY GARRISON-FORT HUACHUCA
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of U.S. ARMY GARRISON-FORT HUACHUCA in LIBBY ARMY AIRFIELD BASE OPERATIONS BLDG 91251, FORT HUACHUCA, AZ 85613 (NAICS 561210). OSHA activity number 335245387.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. ARMY GARRISON-FORT HUACHUCA
- Site address
- LIBBY ARMY AIRFIELD BASE OPERATIONS BLDG 91251
- City
- FORT HUACHUCA
- State
- AZ
- ZIP
- 85613
- Mailing
- INSTALLATION SAFETY OFFICE BLDG 22326 AUGUR AVE, FORT HUACHUCA, AZ 85613
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 450
- Ownership type
- Federal government (D)
Citations
16 citations on file for this inspection.
1926.1101 E01
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(e)(1): All Class I, II, and III asbestos work was not conducted within regulated areas: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, the removal of asbestos-containing floor tile was not conducted within a regulated area. Note: The removal of asbestos-containing floor tile is classified as Class II asbestos work.
Recent events (1)
- · Z (S) $0
1926.1101 F02 I
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, an initial exposure assessment was not conducted to ascertain expected employee exposures during the removal of asbestos-containing floor tile.
Recent events (1)
- · Z (S) $0
1926.1101 F03 I
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(f)(3)(i): The employer failed to conduct daily monitoring that was representative of the exposure of each employee assigned to work in regulated areas and performing Class I or II work: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, daily exposure monitoring was not conducted when asbestos-containing floor tile was removed. Note: The removal of asbestos-containing floor tile is classified as Class II asbestos work.
Recent events (1)
- · Z (S) $0
1926.1101 G01
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(g)(1): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of the exposure: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, engineering controls and work practice controls, such as the following, were not used during the removal of asbestos-containing floor tile: 1) vacuum cleaners equipped with HEPA filters to collect all debris and dust containing Asbestos-Containing Material (ACM) and Presumed Asbestos-Containing Material (PACM); 2) wet methods, or wetting agents, to control employee exposures during asbestos-containing floor tile removal and cleanup, and; 3) prompt clean-up and disposal of wastes and debris contaminated with asbestos in leak-tight containers.
Recent events (1)
- · Z (S) $0
1926.1101 G02
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(g)(2): Control methods were not used to achieve compliance as required by 1926.1101(g)(2)(i) through (g)(2)(v): (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, control methods, such as the following, were not used during the removal of asbestos-containing floor tile: 1) local exhaust ventilation equipped with HEPA filter dust collection systems and, 2) enclosure or isolation of the floor tile removal which produced asbestos dust.
Recent events (1)
- · Z (S) $0
1926.1101 G03 III
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(g)(3)(iii): Dust and debris containing asbestos containing material and presumed asbestos containing material were dry swept, shoveled or removed by other dry clean-up methods: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, debris containing asbestos-containing floor tile was dry swept.
Recent events (1)
- · Z (S) $0
1926.1101 I01
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos that exceed the time weighted average and/or excursion limit in 29 CFR 1926.1101(c) or for which a required negative exposure assessment was not produced: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, exposed employees were not provided nor required to wear protective clothing during the removal of asbestos-containing floor tile. Note: A negative exposure assessment was not produced to demonstrate that employee exposure during the removal of asbestos-contain floor tile was expected to be consistently below the PELs.
Recent events (1)
- · Z (S) $0
1926.1101 I03
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(i)(3): Contaminated clothing was not transported in sealed impermeable bags, or other closed, impermeable containers: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, employees wore their own personal clothing during the removal of asbestos-containing floor tile and, at the end of the day, they wore their contaminated clothing home.
Recent events (1)
- · Z (S) $0
1926.1101 J01 I
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(j)(1)(i): The employer did not establish a decontamination area that was adjacent and connected to the regulated area for the decontamination of employees: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, a decontamination area was not established next to the area where asbestos-containing floor tile was removed. Note: The area where asbestos-containing floor tile is removed is considered a regulated area.
Recent events (1)
- · Z (S) $0
1926.1101 K02 I
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(2)(i): Before work subject to this standard was begun, building and facility owners did not determine the presence, location, and quantity of ACM and/or PACM at the work site pursuant to paragraph (k)(1) of this section: (a) Fort Huachuca, DPTMS, Building 91251: The presence, location, and quantity of asbestos-contained in the floor tile was not determine prior to its removal which began March 12, 2012.
Recent events (1)
- · Z (S) $0
1926.1101 K09 II
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(9)(ii): Training was not provided prior to or at the time of initial assignment and/or at least annually thereafter for employees likely to be exposed in excess of a permissible exposure limit (PEL) and for employees performing Class I through IV asbestos operations: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, training was not provided to employees who removed asbestos-containing floor tile. Note: The removal of asbestos-containing floor tile is classified as Class II asbestos work.
Recent events (1)
- · Z (S) $0
1926.1101 L02
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(l)(2): Asbestos waste, scrap, debris, bags, containers, equipment, and contaminated clothing consigned for disposal was not collected and disposed of in sealed, labeled, impermeable bags or other closed, labeled, impermeable containers: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, pieces of broken asbestos-containing floor tile and other debris were dry swept into piles with a broom and dustpan then placed in a dumpster without being contained in sealed bags or containers.
Recent events (1)
- · Z (S) $0
1926.1101 M01 I A
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(m)(1)(i)(A): The employer did not institute a medical surveillance program for all employees who for a combined total of 30 or more days per year were engaged in Class I, II and III work or were exposed at or above a permissible exposure limit: (a) Fort Huachuca, DPTMS, Building 91251: Employees who removed asbestos-containing floor tile during the period of March 12, 2012 to June 8, 2012 were not included in a medical surveillance program. Note: The removal of asbestos-containing floor tile is classified as Class II asbestos work.
Recent events (1)
- · Z (S) $0
1926.1101 K02 II
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(2)(ii): The building and/or facility owner(s) did not notify prospective employers, tenants, employees of the owner, and all employers of employees who would be performing work within adjacent areas of the presence, location, and quantity of asbestos containing material or presumed asbestos containing material, at the work sites in their buildings and facilities in writing, or a personal communication between the owner and the person to whom notification must be given or their authorized representatives: (a) Fort Huachuca, DPTMS, Building 91251: Employees and employee representatives did not receive notification of the presence, location and quantity of asbestos-containing floor tile.
Recent events (1)
- · Z (O) $0
1926.1101 K07 I
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(7)(i): Warning signs that demarcated the regulated area were not provided and displayed at each location where a regulated area is required to be established by paragraph (e) of this section. (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, warning signs were not provided and displayed when asbestos-containing floor tile was removed. Note: The area where asbestos-containing floor tile is removed is considered a regulated area.
Recent events (1)
- · Z (O) $0
1926.1101 K08 I
- Issued
- Oct 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(8)(i): Labels were not affixed to all products containing asbestos and to all containers containing such products, including waste containers: (a) Fort Huachuca, DPTMS, Building 91251: On or about June 8, 2012 and at time prior thereto, the removed asbestos-containing tile, pieces of broken asbestos-containing tile, and dry sweepings from the floor were disposed of in an unlabeled dumpster.
Recent events (1)
- · Z (O) $0
More inspections at U.S. Army Garrison-Fort Huachuca
View U.S. Army Garrison-Fort Huachuca's full OSHA safety record →
More inspections in this industry (NAICS 561210)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335245387.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.