Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE GOLUB CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE GOLUB CORPORATION in 501 DUANESBURG RD., SCHENECTADY, NY 12306 (NAICS 493110). OSHA activity number 335294781.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Golub Corporation — free Get an email when a new federal OSHA severe-injury report for The Golub Corporation is published. One employer, no account, unsubscribe in one click.
Site address
501 DUANESBURG RD.
City
SCHENECTADY
State
NY
ZIP
12306
Mailing
501 DUANESBURG RD., SCHENECTADY, NY 12306
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
1200
Ownership type
A

4 citations on file for this inspection.

1910.134 H03 I B

Serious Gravity 5 1 instance 8 exposed
Issued
Dec 4, 2012
Penalty
Initial $3,400 · Current $2,500 Reduced
29 CFR 1910.134(h)(3)(i)(B):  Respirators maintained for use in emergency situations were not inspected at least monthly and in accordance with manufacturer recommendations:    (a)  Response trailer - on or about July 19, 2012, monthly inspection procedure for eight (8) Scott Air Paks 4.5 did not follow the manufacturer's recommendations.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3400

1910.119 D03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 4, 2012
Abate by
Jan 8, 2013
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.119(d)(3)(ii):  The employer did not document that equipment complies with recognized and generally accepted good engineering practices.    a) Roof of main building- On or about July 18, 2012, the pressure relief valves for the Low Temp Suction AU#1-#13& 39 were installed to discharge approximately 57 inches above the roof line of the building.
Recent events (2)
  • — I (S) $4250
  • — Z (S) $4250

1910.119 E03 V

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 4, 2012
Abate by
Jan 8, 2013
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1910.119(e)(3)(v):  The process hazard analysis did not address facility siting.      A) Roof of main building- On July 18, 2012, and at times prior thereto, the process hazard analysis did not address facility siting hazards associate with location of pressure relief valve(s) for air handling units on the roof and proximity to employee work location(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4250

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and cables were used as a substitute for the fixed wiring of a structure.     (a) Mechanical Room - On or about July 18, 2012, a flexible 120 V cord was used to power to a solenoid on the air compressor for the pneumatic valves.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Golub Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335294781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.