Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D & K COATING TECHNOLOGIES INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of D & K COATING TECHNOLOGIES INC in 1400 VENTURE DRIVE, JANESVILLE, WI 53548 (NAICS 326113). OSHA activity number 335325163.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & K Coating Technologies INC — free Get an email when a new federal OSHA severe-injury report for D & K Coating Technologies INC is published. One employer, no account, unsubscribe in one click.
Site address
1400 VENTURE DRIVE
City
JANESVILLE
State
WI
ZIP
53548
Mailing
1400 VENTURE DRIVE, JANESVILLE, WI 53548
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:  Mix room 2 Gauver coating tray, with flammable liquids, was ignited by static electricity.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4500

1910.132 D01 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:  Employees work around flammable liquids were not wearing static dissipating footware.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.134 C02 I

Other-than-serious 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.134(c)(2)(i):   Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  Information in Appendix D was not provided for employees voluntarily using a half mask respirator to protect themselves from organic vapors.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

1910.134 C02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  A medical evaluation was not provided for employees voluntarily using a half mask respirator to protect themselves from organic vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee(s) ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  A medical evaluation was not provided for employees voluntarily using a half mask respirator to protect themselves from organic vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 19, 2012
Abate by
Oct 11, 2012
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  In mix room 2 there was an unguarded smooth half inch shaft (diameter) protruding 2 inches from an electric motor.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

View D & K Coating Technologies INC's full OSHA safety record →