Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEEL BUILDING COMPONENTS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of STEEL BUILDING COMPONENTS, INC. in 2960 WOODBRIDGE AVE., EDISON, NJ 08837 (NAICS 332322). OSHA activity number 335339784.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steel Building Components, INC. — free Get an email when a new federal OSHA severe-injury report for Steel Building Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2960 WOODBRIDGE AVE.
City
EDISON
State
NJ
ZIP
08837
Mailing
2960 WOODBRIDGE AVE., EDISON, NJ 08837
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
112
Ownership type
A

6 citations on file for this inspection.

1910.95 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 19, 2012
Abate by
Jan 31, 2013
Penalty
Initial $4,900 · Current $3,185 Reduced

Hazardous substances 8110

29 CFR 1910.95(b)(1): Employees were exposed to sound levels exceeding those listed in Table G-16 of the Subpart G of 29 CFR 1910 and feasible administrative or engineering controls were not utilized to reduce sound levels:    a) Super Stud Building Products, Inc./Edison, NJ site - Production Room: The employer failed to provide feasible administrative or engineering controls to reduce noise levels in the production area, where employees are exposed to continuous noise levels of: 93.87 dBA (machine operator #3, F Line), 92.64 dBA (for machine operator #5, G Line), and 92.98 dBA (for machine operator #6, P Line), which is equivalent to doses of 171.10%, 144.30%, and 151.20% respectively. These levels exceed OSHA Permissible Exposure Limit (PEL) of 90 dBA. Sampling time was 448 minutes, 434 minutes, and 433 minutes respectively.  Zero exposures were assumed for all unsampled time periods.    Condition observed on or about July 23, 2012.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

1910.95 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 19, 2012
Abate by
Dec 4, 2012
Penalty
Initial $4,900 · Current $3,185 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program, as described in 29 CFR 1910.95 (c) through (n) was not instituted, when employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels:     a) Super Stud Building Products, Inc./Edison, NJ site - Production Room: The employer did not provide a continuing effective Hearing Conservation Program for employees exposed to noise levels above 85 dBA. Employees working in the production area were exposed to continuous noise levels of : 87.31 dBA (machine operator #1, P Line),  89.17dBA (for machine operator #2, P Line), 94.60 dBA (for machine operator #3, F Line), 88.95 dBA (machine operator #4, F Line), 93.30 dBA (for machine operator #5, G Line), and 89.6293.60 dBA (for machine operator #6, P Line) for an 8-hour TWA, , which is equivalent to doses of  68.94%, 89.20%, 190.20%, 86.88%, 158.70% and 164.80% respectively.  These levels exceeded OSHA Action Level of 85 dBA. Sampling time was 452 minutes, 454 minutes, 448 minutes, 447 minutes, 434 minutes, and 433 minutes respectively.  Zero exposures were assumed for all unsampled time periods.    Condition observed on or about July 23, 2012.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

1910.95 D01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 19, 2012
Abate by
Dec 4, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(d)(1): A representative monitoring program was not developed and implemented when information indicated that an employee's exposure may equal or exceed and 8 hour time weighted average of 85 dBA:    a) Super Stud Building Products, Inc./Edison, NJ site - Production Room: The employer did not monitor noise exposure for the employees working in the production area. Employees working in the production area were exposed to continuous noise levels of : 87.31 dBA (machine operator #1, P Line),  89.17dBA (for machine operator #2, P Line), 94.60 dBA (for machine operator #3, F Line), 88.95 dBA (machine operator #4, F Line), 93.30 dBA (for machine operator #5, G Line), and 89.6293.60 dBA (for machine operator #6, P Line) for an 8-hour TWA, , which is equivalent to doses of  68.94%, 89.20%, 190.20%, 86.88%, 158.70% and 164.80% respectively.  These levels exceeded OSHA Action Level of 85 dBA. Sampling time was 452 minutes, 454 minutes, 448 minutes, 447 minutes, 434 minutes, and 433 minutes respectively.  Zero exposures were assumed for all unsampled time periods.    Condition observed on or about July 23, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 19, 2012
Abate by
Dec 4, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:    a) Super Stud Building Products, Inc./Edison, NJ site - Production Room: The employer did not establish and maintain an audiometric testing program for the employees working in the production area. Employees working in the production area were exposed to continuous noise levels of : 87.31 dBA (machine operator #1, P Line),  89.17dBA (for machine operator #2, P Line), 94.60 dBA (for machine operator #3, F Line), 88.95 dBA (machine operator #4, F Line), 93.30 dBA (for machine operator #5, G Line), and 89.6293.60 dBA (for machine operator #6, P Line) for an 8-hour TWA, , which is equivalent to doses of  68.94%, 89.20%, 190.20%, 86.88%, 158.70% and 164.80% respectively.  These levels exceeded OSHA Action Level of 85 dBA. Sampling time was 452 minutes, 454 minutes, 448 minutes, 447 minutes, 434 minutes, and 433 minutes respectively.  Zero exposures were assumed for all unsampled time periods.    Condition observed on or about July 23, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 19, 2012
Abate by
Dec 4, 2012
Penalty
Initial $2,800 · Current $1,820 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Super Stud Building Products, Inc./Edison, NJ site - Throughout the facility: A written Hazard Communication Program was not provided where employees are exposed to chemicals, including but not limited to:  - toluene, acetone, and xylene (contained in Touch n'Tone, All-purpose Household Spray Paint),  - acetone and xylene (contained in Rust Oleum Ultra Cover 2X).    Condition observed on/or about July 23, 2012.
Recent events (2)
  • — I (S) $1820
  • — Z (S) $2800

1910.1200 H01

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 19, 2012
Abate by
Dec 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area:    a) Super Stud Building Products, Inc./Edison, NJ site: Throughout the facility: Employees were not provided with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard was introduced into their work area. Employees are exposed to chemicals, such as but not limited to:   - toluene, acetone, and xylene (contained in Touch n'Tone, All-purpose Household Spray Paint),  - acetone and xylene (contained in Rust Oleum Ultra Cover 2X).     Condition observed on/or about July 23, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Steel Building Components, INC.'s full OSHA safety record →