Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J-YONG CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J-YONG CONSTRUCTION in CHALAN INDA - PAGO BAY TRACT 2611 LOT 7-5 BLOCK 1, CHALAN PAGO, GU 96910 (NAICS 236115). OSHA activity number 335448437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J-Yong Construction — free Get an email when a new federal OSHA severe-injury report for J-Yong Construction is published. One employer, no account, unsubscribe in one click.
Establishment
J-YONG CONSTRUCTION
Site address
CHALAN INDA - PAGO BAY TRACT 2611 LOT 7-5 BLOCK 1
City
CHALAN PAGO
State
GU
ZIP
96910
Mailing
PO BOX 315764, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.404 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.404(a)(2):     A grounded conductor was attached to a terminal or lead so as to reverse designated polarity:  (a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY)    (a) Residential Project Chalan Inda Pago Bay Chalan Pago: On July 30, 2012 and at times prior thereto, outlets providing temporary power to the site through flexible cords were wired to a lead so as to reverse designated polarity.  Employees were exposed to electric shock and burns.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.404 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i):     General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    (a) Residential Project Chalan Indu Pago Bay Chalan Pago: On July 30, 2012 and at times prior thereto, temporary power to the site was not equipped with ground fault circuit interrupters nor was an assured equipment grounding program in place at the site.  Employees were exposed to electric shock and burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY)    (a) Residential Project Chalan Inda Pago Bay Chalan Pago: On July 30, 2012 and at times prior thereto, the path to ground between the temporary power and the Rigid Hammer Drill used as a wet mortar mixer was not permanent and continuous.  The yellow extension cord transmitting power to the tool was missing its ground pin.  Employees were exposed to electric shock and burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    (a) Residential Project Chalan Inda Pago Bay Chalan Pago: On July 30, 2012 and at times prior thereto, the supported scaffold legs did not bear on base plates nor other adequate firm foundation.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.1052 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.1052(c)(1)(ii):     Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge:    (a) Residential Project Chalan Indu Pago Bay Chalan Pago interior main stairway: On July 30, 2012 and at times prior thereto the unprotected sides of the stairway to the second floor was not equipped with a stairrail system at the west side and east side of the lower stairway to the mid-level landing and the west side of the stairway above the mid-level landing.  Employees were exposed to falls a distance of up to ten feet, six inches to the concrete floor below.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.501 B01

Repeat Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2013
Abate by
Feb 13, 2013
Penalty
Initial $3,200 · Current $2,400 Reduced
29 CFR 1926.501(b)(1):     Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    (a) Residential Project Chalan Inda Pago Bay Chalan Pago: On July 30, 2012 and at times prior thereto employees were exposed to falls a distance of twelve feet, five inches from the back patio roof at the southwest corner of the project to the ground below.      J YONG CONSTRUCTION WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314656752 CITATION NUMBER 1, ITEM NUMBER 2, ISSUED ON NOVEMBER 17, 2010 AND CONFIRMED AS A FINAL ORDER ON DECEMBER 10, 2010 WITH RESPECT TO A WORKPLACE LOCATED AT E.T. CALVO WAY, MAITE, GUAM.
Recent events (2)
  • — I (R) $2400
  • — Z (R) $3200

View J-Yong Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335448437.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.