OSHA Inspection: CORCO CHEMICAL CORPORATION

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of CORCO CHEMICAL CORPORATION in 299 CEDAR LANE, FAIRLESS HILLS, PA 19030 (NAICS 424690). OSHA activity number 335448619.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corco Chemical Corporation — free Get an email when a new federal OSHA severe-injury report for Corco Chemical Corporation is published. One employer, no account, unsubscribe in one click.
Site address
299 CEDAR LANE
City
FAIRLESS HILLS
State
PA
ZIP
19030
Mailing
299 CEDAR LANE, FAIRLESS HILLS, PA 19030
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424690
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.151 C

Repeat Gravity 10 3 instances 4 exposed
Issued
Sep 28, 2012
Abate by
Oct 3, 2012
Penalty
Initial $6,160 · Current $6,160

Hazardous substances 0020143018602310

29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Lab: An employee, Marketing Manager, conducts quality assurance checks on corrosive chemicals sold by the facility including but not limited to hydrofluoric acid and nitric acid.  There was no eyewash equipment available in the work area that could supply adequate amounts of flushing fluids to the eyes, on or about 07/27/2012.    b) Acid Filling Room: Employees, Operators, are exposed to chemical splashes to body, face and eyes by corrosive chemicals including, but not limited to, nitric acid, hydrofluoric acid, and acetic acid.  Water flow was partially blocked in the right eye cup of the combination eyewash/shower unit and one quart eye wash bottles maintained in the area would not supply an adequate flow of flushing fluid to the eyes, on or about 7/27/2012.    	  c) Distillation Room:  An employee, Warehouse Supervisor, is exposed to chemical splashes to the body, face, and eyes while filling 55 gallon drums of hydrochloric acid and nitric acid.  The safety shower handle was not 69 inches or less from the level on which the user stands, on or about 7/27/2012.      Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.    CORCO CHEMICAL, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD (1910.151c) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314724550, CITATION NUMBER1, ITEM NUMBER 1, AND WAS AFFIRMED AS A FINAL ORDER ON 12/20/2011, WITH RESPECT TO A WORKPLACE LOCATED AT TYBURN ROAD AND CEDAR LANE, FAIRLESS HILLS, PA 19030.
Recent events (1)
  • — Z (R) $6160

1910.1200 F05 I

Repeat 1 instance 3 exposed
Issued
Sep 28, 2012
Penalty
Initial $220 · Current $220

Hazardous substances 0020

29 CFR 1910.1200(f)(5)(i):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:     a) Tanks Behind Acid Filling Room: An acetic acid tank was not labeled with the identity of the chemicals contained within, on or about 07/27/2012.    No abatement certification or documentation required.    CORCO CHEMICAL, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD [1910.1200(f)(5)(i)] WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314724550, CITATION NUMBER 1, ITEM NUMBER 2A, AND WAS AFFIRMED AS A FINAL ORDER ON 12/20/2011, WITH RESPECT TO A WORKPLACE LOCATED AT TYBURN ROAD AND CEDAR LANE, FAIRLESS HILLS, PA 19030.
Recent events (1)
  • — Z (R) $220

1910.1200 F05 II

Repeat 1 instance 3 exposed
Issued
Sep 28, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 0020

29 CFR 1910.1200(f)(5)(ii):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    a) Tanks Behind Acid Filling Room: An acetic acid tank was not labeled with the hazards of the chemicals contained within, on or about 07/27/2012.    No abatement certification or documentation required.    CORCO CHEMICAL, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD [1910.1200(f)(5)(ii)] WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER  314724550, CITATION NUMBER 1, ITEM NUMBER 2A, AND WAS AFFIRMED AS A FINAL ORDER ON 12/20/2011, WITH RESPECT TO A WORKPLACE LOCATED AT TYBURN ROAD AND CEDAR LANE, FAIRLESS HILLS, PA 19030.