ITHACA, NY —
OSHA Inspection: STORK H&E TURBO BLADING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STORK H&E TURBO BLADING in 334 COMFORT RD., ITHACA, NY 14850 (NAICS 336412). OSHA activity number 335454609.
Where did this inspection happen?
- Establishment
- STORK H&E TURBO BLADING
- Site address
- 334 COMFORT RD.
- City
- ITHACA
- State
- NY
- ZIP
- 14850
- Mailing
- 334 COMFORT RD, ITHACA, NY 14850
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 100
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $2700.00
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) Stork H & E Turbo Blading Inc., on or about 7/24/12: Training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage firefighting. *ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (1)
- — Z (S) $2700
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $3600.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Polish Department, on or about 7/24/12: Several Bador sanders were not provided with guards at the ingoing nip points of the belts and rollers. b) Tool Room, on or about 7/24/12: Knuth drill press was not provided with a chuck guard. c) CNC Department, on or about 7/24/12: Mini Bador sander was not provided with a guard at the ingoing nip points of the belt and roller. d) CNC Department, on or about 7/24/12: Ultima Acer milling machine was not provided with a chuck guard. e) Square-Up Department, on or about 7/24/12: Three (3) Raambaudi Ram milling machines were not provided with chuck guards. f) CNC Department, on or about 7/24/12: Okkuma CNC machines had the door interlocks disconnected thereby allowing operators access to inside the machine during operation.
Recent events (1)
- — Z (S) $3600
1910.215 A02
- Issued
- Penalty
- Initial $3600.00 · Current $3600.00
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) Cutter/Grinder Area, on or about 7/24/12: Baldor pedestal grinder was not provided with a safety guard that covered the spindle end, nut and flange projections. b) CNC Department, on or about 7/24/12: Baldor grinder behind CNC #30 was not provided with a safety guard that covered the spindle end, nut and flange projections.
Recent events (1)
- — Z (S) $3600
1910.215 A04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) Cutter/Grinder Area, on or about 7/24/12: Baldor pedestal grinder was not provided with a work rest to support off-hand grinding of cutter tips.
Recent events (1)
- — Z (S) $0
More inspections at STORK H&E TURBO BLADING
ITHACA, NY—2013-08-01 00:00:00
STORK H&E TURBO BLADING
ITHACA, NY—2012-07-24 00:00:00
STORK H&E TURBO BLADING
View STORK H&E TURBO BLADING's full OSHA safety record →
More inspections in this industry (NAICS 336412)
STUART, FL—2026-06-16
TURBOCOMBUSTOR TECHNOLOGY, INC.
TRAVERSE CITY, MI—2026-06-15
SKILLED MANUFACTURING INC
WHITEHALL, MI—2026-06-02
HOWMET AEROSPACE INC
HILLSDALE, MI—2026-05-12
COBRA MOTO LLC
MADISONVILLE, KY—2026-04-21
69032 - GENERAL ELECTRIC COMPANY
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335454609.