OSHA Inspection: RM BUILDINGS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RM BUILDINGS INC. in RT. 50, BRIDGEPORT, WV 26330 (NAICS 236116). OSHA activity number 335472189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RM Buildings INC. — free Get an email when a new federal OSHA severe-injury report for RM Buildings INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RM BUILDINGS INC.
Site address
RT. 50
City
BRIDGEPORT
State
WV
ZIP
26330
Mailing
RT.2 BOX 271 B, LOST CREEK, WV 26385
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
9
Ownership type
A

7 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $1,320 · Current $1,056 Reduced
29 CFR 1926.95(a):     Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    a. Post Frame Building Under Construction: Employees performing various construction operations such as but not limited to installing the top section of the piggy back trusses where tools and materials were being handled were wearing tennis shoes in lieu of substantial work boots as observed on 7-23-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $1056
  • — Z (S) $1320

1926.404 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $1,320 · Current $1,056 Reduced
29 CFR 1926.404(b)(1)(ii):     Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    a. Honda EM 6500 SX Generator: There was no ground fault circuit interrupter protection for employees that were using tools such as but not limited to the Makita circula saw that was being energized by the generator as determined on 7-23-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $1056
  • — Z (S) $1320

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $2,200 · Current $1,760 Reduced
29 CFR 1926.451(g)(1):     Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection:    a. Haulotte Scissor Lift: Employees were exposed to fall hazards estimated to be 18 feet as they stood on the mid rail and straddled the top rail of the guard rail system of the lift while installing plywood as determined on 7-23-12.    b. Haulotte Scissor Lift: Employees were exposed to a fall of approximately 14 feet due to the mid rail at the access area of the lift was tied up to the top rail resulting in an opening 28 inches wide by 42 inches tall making the guard rail system incomplete as determined on 7-23-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $1760
  • — Z (S) $2200

1926.20 B02

Repeat Gravity 5 1 instance 9 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $4,400 · Current $3,520 Reduced
29 CFR 1926.20(b)(2):     The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)    a. Post Frame Building Under Construction:  A competent person did not perform frequent a regular inspections of the job site, materials and equipement per information provided by the employer and also due to the number and nature of the hazards observed on the site such as but not limited to employees exposed to fall hazards as determined on 7-23-12.    RM BUILDINGS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.20(b)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313369142, CITATION NUMBER 1, ITEM NUMBER 4b, ISSUED ON 8-18-2009. THIS ITEM BECAME FINAL ORDER ON 9-24-2009, AND ABATEMENT WAS CERTIFIED ON 9-09-2009 WITH RESPECT TO A WORKPLACE LOCATED AT TAYLOR COUNTY FAIRGROUNDS, US RT.50, GRAFTON, WV.    Abatement Documentation Required For This Item
Recent events (2)
  • — I (R) $3520
  • — Z (R) $4400

1926.100 A

Repeat Gravity 1 1 instance 7 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $2,640 · Current $2,112 Reduced
29 CFR 1926.100(a):     Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a.Post Frame Building Under Construction: No employee on site was wearing a hard hat whether they were on the roof area working below other employees on the roof, or whether they were on the roof working above the employees working / walking on the decked area below them inside the trusses or employees walking / working on the ground below the employees on the decked area as observed on 7-23-12.    RM BUILDINGS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.20(b)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313369142, CITATION NUMBER 1, ITEM NUMBER 5, ISSUED ON 8-18-2009. THIS ITEM BECAME FINAL ORDER ON 9-24-2009, AND ABATEMENT WAS CERTIFIED ON 9-09-2009 WITH RESPECT TO A WORKPLACE LOCATED AT TAYLOR COUNTY FAIRGROUNDS, US RT.50, GRAFTON, WV.    Abatement Documentation Required For This Item
Recent events (2)
  • — I (R) $2112
  • — Z (R) $2640

1926.501 B01

Repeat Gravity 5 1 instance 5 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $4,400 · Current $3,520 Reduced
29 CFR 1926.501(b)(1):     Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a. Roof of the Post Frame Wood Building Under Construction: Employees were exposed to falls ranging in height from approximately 13 feet down between the 22 1/2 inch spaces between the trusses to the decked area below and also approximately 18 feet from the eave of the roof to the ground while installing the piggy back sections of the wooden trusses on the 8 in 12 sloped roof as observed on 7-23-12.    b.  Decked Area Inside the Trusses: Employees were exposed to falls of approximately 18 feet while walking / working from the decked area of the trusses due to the opening between the uprights of the trusses had a distance of approximately 22 1/2 inches where employees could fall as determined on 7-23-12.    RM BUILDINGS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.501(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313369142, CITATION NUMBER 1, ITEM NUMBER 8a, ISSUED ON 8-18-2009. THIS ITEM BECAME FINAL ORDER ON 9-24-2009, AND ABATEMENT WAS CERTIFIED ON 9-09-2009 WITH RESPECT TO A WORKPLACE LOCATED AT TAYLOR COUNTY FAIRGROUNDS, US RT.50, GRAFTON, WV.          Abatement Certification Is Required For This Item
Recent events (2)
  • — I (R) $3520
  • — Z (R) $4400

1910.1200 G08

Other-than-serious 1 instance 3 exposed
Issued
Jan 9, 2013
Abate by
Jan 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):     The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (Construction Reference: 1926.59)    a. Post Frame Wood Building Under Construction: The employer did not have a material safety data sheet on site for the DAP Subfloor Adhesive which was labeled a flammable and contained ingredients such as but not limited to toluene and petroleum distillates as determined on 7-23-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View RM Buildings INC.'s full OSHA safety record →