Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TWC ARCHITECTURAL MOULDINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TWC ARCHITECTURAL MOULDINGS in 8523 NE LOOP 410, SAN ANTONIO, TX 78219 (NAICS 321113). OSHA activity number 335523981.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TWC Architectural Mouldings — free Get an email when a new federal OSHA severe-injury report for TWC Architectural Mouldings is published. One employer, no account, unsubscribe in one click.
Site address
8523 NE LOOP 410
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
8523 NE LOOP 410, SAN ANTONIO, TX 78219
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
29
Ownership type
A

6 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    Gang Rip, Model 524-DC/SR4, S/N:MJ-7377, On or about 8/2/12 and at times prior thereto employees were exposed to an amputation hazard when bypassing a guard and removing dust from the dust collector.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.157 C01

Serious Gravity 1 1 instance 29 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    On or about 8/2/12 and at times prior thereto, in case of an emergency, employees were exposed to a trip hazard from several boards that were stacked in front of the fire extinguisher.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Prime Area, ENCO Milling Machine Model: 100-1599, S/N 10502: On or about 8/2/12 and at times prior thereto employees were exposed to an amputation hazard when milling keyways into shafts measuring approximately 5" in length by 1.5" diameter.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:                                                                                                       Prime Area, ENCO Milling Machine Model: 100-1599, S/N 10502: On or about 8/2/12 and at times prior thereto employees were exposed to an amputation hazard when milling keyways into shafts measuring approximately 5" in length by 1.5" diameter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C04 I

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:    a) Near the Rough Mill, On or about 8/2/12 and at times prior thereto employees were exposed to a rotating shaft measuring approximately 1 in. length x 3 in. diamter and containing a set screw, while stacking material from the mill.     b) Near the Weinig Gruppe Power, Model: Power Pat-500 S/N 107444: On or about 8/2/12 and at times prior thereto employees were exposed to a rotating shaft measuring approximately 6 in. length by 1 in. diameter when stacking wood mouldings.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 6, 2012
Abate by
Sep 21, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Prime Area,  On or about 8/2/12 and at times prior thereto employees were exposed to an electrical shock of 120 volts from a junction box that was being used as an outlet.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

View TWC Architectural Mouldings's full OSHA safety record →