Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: SOUTHBRIDGE SHEET METAL WORKS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTHBRIDGE SHEET METAL WORKS, INC. in 441 MAIN STREET, STURBRIDGE, MA 01518 (NAICS 332322). OSHA activity number 335601381.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southbridge Sheet Metal Works, INC. for free Get an email when a new federal OSHA severe-injury report for Southbridge Sheet Metal Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
441 MAIN STREET
City
STURBRIDGE
State
MA
ZIP
01518
Mailing
P.O. BOX 517, STURBRIDGE, MA 01566
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
45
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 19, 2012
Penalty
Initial $4,900 · Current $2,500 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing for likely to cause death or serious physical harm to employees in that employees were exposed to struck-by, caught-in, and/or amputation hazards: (a) In the CNC area for employees operating the Supermax Max 3, Rebel CNC machine, where the CNC machine was not equipped with a functioning door interlock device exposing employees to the potential hazard of being struck by parts expelled from the machine center or being caught in the moving machinery by opening the machine door during the operating cycle. Among other methods, one feasible and acceptable abatement method to correct this hazard is to install a door interlock device on the Supermax Max 3, Rebel CNC machine as required by ANSI B11.2-2002, Requirements for Turning Centers Automatic Numerically Controlled Turning Machines, paragraphs 6.21 Safeguarding and 6.21.1.2 Automatic Mode which states: 1. Paragraph 6.21: Machines shall be safeguarded wherever practical by fixed or interlocked moveable guards. 2. Paragraph 6.21.1.2: Machine operation shall only be possible when the guards are closed and the safeguarding (protective) devices are active. If it is possible, in this mode, to open an interlocked moveable guard, the hazardous movement shall cease and be inhibited.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $4900

1910.242 B

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Aug 21, 2012
Abate by
Aug 22, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    CNC area, Southbridge Sheet Metal Works, 441 Main Street, Sturbridge, Massachusetts:  Employees working at the CNC machines were using compressed air, regulated to approximately 95 pounds, to clean chips off of machined pieces exposing them to struck by hazards from flying materials.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2100

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2012
Abate by
Aug 22, 2012
Penalty
Initial $3,500 · Current $1,300 Reduced

Hazardous substances 8870

29 CFR 1910.303(b)(7)(i):     Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    Welding area across from main electrical service room, Southbridge Sheet Metal Works;  480 volt electrical disconnect box DS 7 at the welding station had a missing knockout that was greater than 1 inch in diameter that would allow employees to access the energized parts exposing them to electric shock and electrocution hazards.
Recent events (2)
  • · I (S) $1300
  • · Z (S) $3500

1910.334 A02 I

Other-than-serious 1 instance 45 exposed
Issued
Aug 21, 2012
Abate by
Aug 28, 2012
Penalty
Initial $2,100 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    Facility wide, Southbridge Sheet Metal Works; Employees used extension cords for a variety of reasons such as powering fans and person radios as well as providing power to computers and other work related tools, however, the cords were not inspected to check for damage to the cord prior to use exposing the employees to electric shock and burn hazards as well as fire hazards.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2100

1910.184 D

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2012
Abate by
Aug 22, 2012
Penalty
Initial $4,200 · Current $2,500 Reduced
29 CFR 1910.184(d):     Damaged or defective sling(s) were not immediately removed from service:      Welding area across from main electrical service room, Southbridge Sheet Metal Works; Employee was using damaged sling to move machined metal piece to work table exposing the employee to struck by hazards and laceration hazards.    Southbridge Sheet Metal Works, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.184(d) which was contained in OSHA inspection number 315514745, citation number 1-3a and 1-3b, issued on September 15, 2011, with respect to a workplace located at 441 Main Street, Sturbridge, Massachusetts. The final order date for the citation was on October 6, 2011.
Recent events (2)
  • · I (S) $2500
  • · Z (R) $4200

1910.303 G01

Other-than-serious 1 instance 45 exposed
Issued
Aug 21, 2012
Abate by
Aug 22, 2012
Penalty
Initial $700 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment      Main Electrical Service Room, Southbridge Sheet Metal Works, Inc.;  A rolling trash barrel was left in front of the door of the main electrical service room preventing unimpeded access to the electrical room in an emergency.
Recent events (2)
  • · I (O) $0
  • · Z (O) $700

View Southbridge Sheet Metal Works, INC.'s full OSHA safety record →