WESTWORTH VILLAGE, TX —
OSHA Inspection: MATRIX INTERIOR CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MATRIX INTERIOR CONSTRUCTION, INC. in 6600 WESTWORTH BLVD, WESTWORTH VILLAGE, TX 76114 (NAICS 238130). OSHA activity number 335669586.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATRIX INTERIOR CONSTRUCTION, INC.
- Site address
- 6600 WESTWORTH BLVD
- City
- WESTWORTH VILLAGE
- State
- TX
- ZIP
- 76114
- Mailing
- 1206 TAPPAN CIRCLE, CARROLLTON, TX 75006
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 16
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 25, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. On or about August 8, 2012, employees were observed working from the top level of a blue mobile scaffold that was not fully planked. Employees were exposed to fall hazards from a height greater than 10 feet to the concrete surface below.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1926.451 G01 VII
- Issued
- Jan 25, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about August 8. 2012, for the blue mobile scaffold on the northwest corner of the building project, an employee was performing work from a scaffold without being restrained from a fall by a guardrail system or by a personal fall arrrest system. The employee was exposed to fall hazards at a distance greater than 10 feet to the concrete surface below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Jan 25, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. On or about August 8. 2012, for the blue mobile scaffold on the northwest corner of the building project, a ladder was not provided for accessing the scaffold. The employee climbed up the scaffold components to access the working level and was exposed to fall hazards at a distance greater than 10 feet to the concrete surface below.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1926.451 C02
- Issued
- Jan 25, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about August 8, 2012, for the blue mobile scaffold at the northwest corner of the building project, a caster and wheel had been removed from an upright and the upright was positioned on a piece of scrap wood without a base plate being installed on the upright. Employees were exposed to a fall hazard approximately 10 feet to the concrete surface below.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1926.451 F07
- Issued
- Jan 25, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. On or about August 8, 2012, for mobile scaffolds on the site, no employee had been qualified to erect, dismantle, or alter scaffolds. Employees were exposed to fall hazards resulting from deficiencies such as, but not limited to, a missing base plate, lack of a guardrail system or issuance of personal fall arrest systems, and working levels not being fully planked.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
More inspections at Matrix Interior Construction, INC.
View Matrix Interior Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335669586.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.