Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WATTS, WEBCOR, OBAYASHI AJV

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WATTS, WEBCOR, OBAYASHI AJV in GUAM NAVAL HOSPITAL REPLACEMENT PROJECT, AGANA HEIGHTS, GU 96910 (NAICS 236220). OSHA activity number 335674586.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Watts, Webcor, Obayashi AJV for free Get an email when a new federal OSHA severe-injury report for Watts, Webcor, Obayashi AJV is published. One employer, no account, unsubscribe in one click.
Site address
GUAM NAVAL HOSPITAL REPLACEMENT PROJECT
City
AGANA HEIGHTS
State
GU
ZIP
96910
Mailing
674 HARMON LOOP RD STE 212, DEDEDO, GU 96929
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
140
Ownership type
A

2 citations on file for this inspection.

1926.502 D15

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 19, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    An employee was using an anchorage point (rebar) to tie-off to that was not capable of supporting at least 5,000 pounds.
Recent events (2)
  • · I (S) $0
  • · Z (S) $6300

1926.502 D16 III

Other-than-serious 1 instance 1 exposed
Issued
Oct 19, 2012
Penalty
Initial $0 · Current $3,000
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    An employee was tied-off at his feet which would have allowed the employee to free fall for more than 6 feet and the connection point (rebar) was not certified.
Recent events (2)
  • · I (O) $3000
  • · Z (S) $0

View Watts, Webcor, Obayashi AJV's full OSHA safety record →