OSHA Inspection: CNJ, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CNJ, INC. in 265 TEAGUE COURT, AUBURN, AL 36832 (NAICS 336340). OSHA activity number 335696407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CNJ, INC. — free Get an email when a new federal OSHA severe-injury report for CNJ, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CNJ, INC.
Site address
265 TEAGUE COURT
City
AUBURN
State
AL
ZIP
36832
Mailing
265 TEAGUE COURT, AUBURN, AL 36832
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
82
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $3,500 · Current $2,448 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Lines 1-4's Robotic Arms: On or about July 27, 2012 and at times prior thereto, the employer did not evaluate its lockout tagout program, training, and written procedure, or evaluate the performance of its authorized employees in execution of the lockout tagout procedures which exposed employees to inadvertent start up and/or energy sources (e.g. electrical) of the system.
Recent events (2)
  • — I (S) $2448
  • — Z (S) $3500

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Mar 11, 2013
Penalty
Initial $3,500 · Current $2,448 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) Lines 1-4's Robotic Arms: On or about July 27, 2012 and at times prior thereto, the employer did not ensure the authorized employees were trained to effectively affix lockout devices which exposed employees to inadvertent start up and/or energy sources (e.g. electrical) of the system.
Recent events (2)
  • — I (S) $2448
  • — Z (S) $3500

View CNJ, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335696407.