EL PASO, TX —
OSHA Inspection: TRIMCO MASTER MILLWORKS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TRIMCO MASTER MILLWORKS in 11501 CONFEDERATE, EL PASO, TX 79936 (NAICS 238350). OSHA activity number 335705182.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRIMCO MASTER MILLWORKS
- Site address
- 11501 CONFEDERATE
- City
- EL PASO
- State
- TX
- ZIP
- 79936
- Mailing
- 11501 CONFEDERATE, EL PASO, TX 79936
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 38
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Jan 16, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. On August 08, 2012, and times prior to, saw dust had accumulated in large amount on the floors of the facility. This condition was present throughout the wood working area of the facility exposing employees to trip and fall hazards and potential fire hazards.
Recent events (2)
- — I (O) $500
- — Z (S) $2100
1910.37 A03
- Issued
- Jan 16, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. On August 08, 2012, and times prior to, employees were working inside the building with an emergency exit that was blocked. This condition exposed employee to potential fire hazards.
Recent events (2)
- — I (O) $500
- — Z (S) $3500
1910.178 F01
- Issued
- Jan 16, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.178(f)(1): The storage and handling of liquid fuels such as gasoline and diesel fuel were not in accordance with NFPA Flammable and Combustible Liquids Code (NFPA No. 30-1969), which is incorporated by reference as specified in Sec. 1910.6. On August 08, 2012 and times prior, South side of the facility, three LPG tanks used to provide fuel for the powered industrial trucks were not secured nor stored as per NFPA Flammable and Combustible Liquids Code requirements. This condition exposed employee to possible burns in case of an explosion and/or stuck by hazards.
Recent events (2)
- — I (O) $500
- — Z (S) $3500
1910.303 G01 II
- Issued
- Jan 16, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage. On August 08, 2012, and times prior to, in the main shop, the commercial fabrication area, and the paint booth area, the electrical panels used to control power to the building and other machinery were blocked. In the event of an emergency employees would not have safe access to turn off power to the building.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.304 G05
- Issued
- Jan 16, 2013
- Penalty
- Initial $2,380 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. On August 08, 2012 and times prior to, employees were using a fan that did not have proper grounding therefore energizing the entire outer shell of the fan. This condition exposed employees to electrical shock.
Recent events (2)
- — I (S) $1500
- — Z (S) $2380
1910.305 G02 III
- Issued
- Jan 16, 2013
- Abate by
- Feb 15, 2013
- Penalty
- Initial $4,200 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. On August 08, 2012, and times prior to, employees were using extensions cords without proper tension control devices such as strain reliefs. Cords were suspended from the ceiling and were used to power tools. This condition exposed employees to electrical shock.
Recent events (2)
- — I (S) $1500
- — Z (S) $4200
More inspections at Trimco Master Millworks
View Trimco Master Millworks's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335705182.