Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIMCO MASTER MILLWORKS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TRIMCO MASTER MILLWORKS in 11501 CONFEDERATE, EL PASO, TX 79936 (NAICS 238350). OSHA activity number 336467196.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trimco Master Millworks — free Get an email when a new federal OSHA severe-injury report for Trimco Master Millworks is published. One employer, no account, unsubscribe in one click.
Site address
11501 CONFEDERATE
City
EL PASO
State
TX
ZIP
79936
Mailing
11501 CONFEDERATE, EL PASO, TX 79936
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
38
Ownership type
A

8 citations on file for this inspection.

1910.107 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced

Hazardous substances 0040175022809010

29 CFR  1910.107(c)(2)  The employer did not ensure that no open flame or spark producing equipment was not in any spraying area nor within 20 feet thereof, unless separated by a partition.    On November 1, 2012, employees were found to be spraying highly flammable chemicals such as, but not limited to, organic peroxides and there was no separation or partition from spark producing electrical equipment located in the spraying area such as, but not limited to, light switches, fluorescent lighting, electrical conduit, electrical panels, a microwave, and exhaust fans.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.107 C06

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.107(c)(6)  Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not of explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations.    On November 1, 2012, employees were found to be spraying highly flammable chemicals such as, but not limited to, organic peroxides and spark producing electrical equipment such as, but not limited to, light switches, fluorescent lighting, electrical conduit, electrical panels, a microwave, and exhaust fans were located in the spraying area and had not been explosion proof, approved for Class I, Group D locations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 D02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.107(d)(2)  All spraying areas were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered.     On November 1, 2012, employees were found to be spraying highly flammable chemicals such as, but not limited to, organic peroxides and no mechanical ventilation was available to remove flammable vapors and mists to a safe location so that life is not endangered.  The employer had converted a large, rectangular, metal, hanger building (approx. 2000 sqft.) into the marble spray shop where employees prep sink molds by spraying them with highly flammable chemicals and the only ventilation for the area was the air conditioning vent blowing in clean air and a small, filterless, 10 inch fan located at the far end of the building, which exhausted to an outdoor area employees use as a passageway.  The exhaust fan is incapable of pulling an average air velocity of 100 linear feet per minute and had no means to confine and control combustible residues.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 M01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.107(m)(1)  All spraying operations involving the use of organic peroxides and other dual component coatings were not be conducted in approved sprinklered spray booths meeting the requirements of this section.    On November 1, 2012, employees were found to be spraying organic peroxides and a spray booth with sprinklers was not made available to employees to control flammable mists and vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $3,500 · Current $1,000 Reduced
29 CFR 1910.305(b)(1)(ii) Unused openings in cabinets, boxes, and fittings were not effectively closed.    On November 1, 2012, in the Marble Shop a circuit breaker panel was found with large openings not effectively closed, exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3500

1910.134 C01

Deleted Other-than-serious 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.134(c)(1)  In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable.    On November 1, 2012, employees were found to be spraying organic peroxides and flammable liquids in the Marble Shop.  A respiratory protection program has been in development but worksite specific procedures have yet to be complete to ensure employee safety.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 D01 I

Deleted Other-than-serious 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.134(d)(1)(i)  The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.    On November 1, 2012, employees were found to be spraying organic peroxides and flammable liquids in the Marble Shop.  Employees were found using P100 cartridges when exposed to organic vapors while other employees were found to be using organic vapor cartridges when exposed to particulates.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K01 II

Deleted Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0040175022809010

29 CFR 1910.134(k)(1)(ii) The employer did not ensure that each employee can demonstrate knowledge of at least the following: What the limitations and capabilities of the respirator are.    On November 1, 2012, employees were found to be spraying organic peroxides and flammable liquids in the Marble Shop and employees were improperly using their respiratory protection.  Employees were found using P100 cartridges when exposed to organic vapors while other employees were found to be using organic vapor cartridges when exposed to particulates signaling employees do not fully understand the limitations and capabilities of the different types of respiratory cartridges available to them.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Trimco Master Millworks's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336467196.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.