Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRI-STATE

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of TRI-STATE in 382 LANCASTER AVENUE P.O.B. 4006, MALVERN, PA 19355 (NAICS 332722). OSHA activity number 335709788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tri-State — free Get an email when a new federal OSHA severe-injury report for Tri-State is published. One employer, no account, unsubscribe in one click.
Establishment
TRI-STATE
Site address
382 LANCASTER AVENUE P.O.B. 4006
City
MALVERN
State
PA
ZIP
19355
Mailing
382 LANCASTER AVENUE P.O.B. 4006, MALVERN, PA 19355
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 5 instances 1 exposed
Issued
Sep 13, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) Tri-State Tubular Rivet Co. - The employer had milling and tubular head machines that were being serviced/repaired by an employee who was exposed to the possibility of an unexpected start-up or release of stored energy. This was observed on May 23, 2012.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.147 C04 I

Serious Gravity 5 5 instances 1 exposed
Issued
Sep 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      a) Tri-State Tublar Rivet Co. - The employer failed to develop, document and utilize energy control procedures for their employees who serviced or performed maintenance on hazardous equipment [e.g Milling Machines, Waterbury-Tublar Machines, etc..] within the facility. This was observed on May 23, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 5 instances 1 exposed
Issued
Sep 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):     The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a) Tri-State Tubular Rivet Co. - The employer did not provide training for their employee who routinely repairs and services the Milling and Waterbury-Tubular Head machines. This was observed on May 23, 2012
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Tri-State's full OSHA safety record →