YOSEMITE NATIONAL PARK, CA —
OSHA Inspection: NATIONAL PARKS SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARKS SERVICE in B & G OPERATIONS (BUILDINGS AND GROUNDS) 9000 LOST ARROW DR., YOSEMITE NATIONAL PARK, CA 95389 (NAICS 712190). OSHA activity number 335739389.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL PARKS SERVICE
- Site address
- B & G OPERATIONS (BUILDINGS AND GROUNDS) 9000 LOST ARROW DR.
- City
- YOSEMITE NATIONAL PARK
- State
- CA
- ZIP
- 95389
- Mailing
- P.O. BOX 700W 5083 FORESTA RD., BLDG. B759, EL PORTAL, CA 95318
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 900
- Ownership type
- D
Citations
8 citations on file for this inspection.
1910.101 B
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6: (a) B & G Department - On or about 5/10/12 and at times prior thereto, a nitrogen compressed gas cylinder was missing a cap and subject to being knocked over or damaged. The cylinder was not in use.
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) B & G Department - On or about 5/10/12, and at times prior thereto, a Wissota double wheeled bench grinder; the left wheel had a measured 3/8" gap between the wheel and the work rest and the right wheel had a measured 1/2" gap between the work rest and the wheel.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) B & G Department - On or about 5/10/12, and at times prior thereto: 1. Brown-Brockmeyer double wheeled bench grinder was missing both tongue guards. 2. Wissota double wheeled bench grinder was missing one tongue guard on the right side.
Recent events (1)
- — Z (S) $0
1910.253 A03
- Issued
- Sep 21, 2012
- Abate by
- Oct 15, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved: (a) B & G Department - On or about 5/10/12, and at times prior thereto, it was observed that the pressure gauge of a portable acetylene cylinder had no numbers to indicate safe operating pressure.
Recent events (1)
- — Z (S) $0
1910.253 B05 II Q
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(5)(ii)(Q): A hammer or wrench shall not be used to open cylinder valves. If valves cannot be opened by hand, the supplier shall be notified: (a) B & G - On or about 5/10/12, and at times prior thereto, it was observed that a wrench attached to the stem of an acetylene cylinder was used to control gas flow instead of an approved valve.
Recent events (1)
- — Z (S) $0
1910.303 E01
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: (a) B & G Department - On or about 5/10/12, and at times prior thereto, a Westinghouse stove was energized through an electric box that did not have the following markings: 1. The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product may be identified; 2. Markings giving voltage, current, wattage, or other ratings as necessary.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) B & G Department - On or about 5/10/12, and at times prior thereto, a Westinghouse stove was plugged into an electrical box which was missing the middle knockout.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Sep 21, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) B & G Department - On or about 5/10/12, and at times prior thereto, a Hotpoint refrigerator was energized through a blue extension cord instead of a fixed electrical outlet.
Recent events (1)
- — Z (S) $0
More inspections at National Parks Service
View National Parks Service's full OSHA safety record →
More inspections in this industry (NAICS 712190)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335739389.