OSHA Inspection: E.S. INVESTMENTS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of E.S. INVESTMENTS, LLC in 14055 US HWY 19 N., CLEARWATER, FL 33764 (NAICS 332116). OSHA activity number 335808796.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch E.S. Investments, LLC — free Get an email when a new federal OSHA severe-injury report for E.S. Investments, LLC is published. One employer, no account, unsubscribe in one click.
Site address
14055 US HWY 19 N.
City
CLEARWATER
State
FL
ZIP
33764
Mailing
14055 US HWY 19 N., CLEARWATER, FL 33764
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
80
Ownership type
A

9 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 17, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1):     The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    a)  Stamping Area - An effective program was not maintained and an employee was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about August 15, 2012.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.95 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 17, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(1):     The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:    a)  Stamping Area - An audiogram was not provided for a press operator hired in March 2012 and who was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about November 9, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 K01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 17, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(k)(1):     The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k):    a)  Stamping Area - Training was not provided to a press operator, who was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about October 17, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 10 2 instances 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 3, 2012
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.217(c)(1)(i):     The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es)    a)  Press 46, Stamping Area - Inadequate guarding existed on the front and back of Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012.    b)  Press 46, Stamping Area - A 12 inch by 13 inch unguared opening existed on the side of Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012.
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

1910.217 D09 I

Serious Gravity 10 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(i):     The employer did not establish a die setting procedure for mechanical power presses that would ensure compliance with 29 CFR 1910.217(c):      a)  Press 46, Stamping Area - No procedure was developed for a Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 IV

Serious Gravity 10 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Dec 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(iv):     Safety blocks were not used when mechanical power press dies were being adjusted or repaired in the press:    a)  Press 46, Stamping Area - No blocks were used for a Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)  Press 46, Stamping Area - Four pulleys, the lowest of which was 57 inches above the floor, were not guarded, on or about August 15, 2012.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.219 E03 I

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):     Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):     a)  Press 46, Stamping Area - A vertical belt was not guarded, on or about August 15, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Nov 27, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)  Press 46, Stamping Area - A nozzle provided 62 p.s.i., on or about Auguest 15, 2012.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

View E.S. Investments, LLC's full OSHA safety record →