CLEARWATER, FL —
OSHA Inspection: E.S. INVESTMENTS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of E.S. INVESTMENTS, LLC in 14055 US HWY 19 N., CLEARWATER, FL 33764 (NAICS 332119). OSHA activity number 347095465.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E.S. INVESTMENTS, LLC
- Site address
- 14055 US HWY 19 N.
- City
- CLEARWATER
- State
- FL
- ZIP
- 33764
- Mailing
- 14055 US HWY 19 N., CLEARWATER, FL 33764
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 120
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.242 B
- Issued
- Feb 27, 2024
- Abate by
- Apr 12, 2024
- Penalty
- Initial $8,296 · Current $4,978 Reduced
General-duty citation text
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes and the compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a. At the 14055 US Hwy 19 N. Clearwater, FL: On or about November 11, 2023, the employer exposed employees to eye hazards, in that, an employee was using a pneumatic gun to blow built-up debris while the stamping machine was running, during which time the compressed air supplied to the pneumatic gun from the air compressor was set to 80 PSI and the air gun was not equipped with a safety tip nozzle nor was effective chip guarding used on the gun therefore exposing the employee to the hazards of the release of the compressed air and flying debris.
Recent events (2)
- — I (S) $4977.6
- — Z (S) $8296
More inspections at E.S. Investments, LLC
View E.S. Investments, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332119)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347095465.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.