OSHA Inspection: M. & H. CRATES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M. & H. CRATES, INC. in 4022 FM 347 NORTH, JACKSONVILLE, TX 75766 (NAICS 321920). OSHA activity number 335825394.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M. & H. Crates, INC. — free Get an email when a new federal OSHA severe-injury report for M. & H. Crates, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4022 FM 347 NORTH
City
JACKSONVILLE
State
TX
ZIP
75766
Mailing
4022 FM 347 NORTH, JACKSONVILLE, TX 75766
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
65
Ownership type
A

4 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 10, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.    This violation most recently occurred on August 14, 2012, in the nailing room, where the employer did not ensure that employees using pneumatic nailers to secure pallets wore appropriate eye protection.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.147 C01

Serious Gravity 10 1 instance 7 exposed
Issued
Jan 4, 2013
Abate by
Jan 10, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machines or equipment were not isolated from the energy source and rendered inoperative.    This violation most recently occurred on August 14, 2012, in the nailing room, the employer did not develop and implement hazardous energy controls programs when servicing and maintaining machines and equipment including, but not limited the Viking pallet nail machine.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.219 F03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 4, 2013
Abate by
Jan 10, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.219(f)(3) All sprockets wheels and chains, seven (7) feet or less above the florr platform, were not enclosed.    This violation most recently occurred on August 14, 2012, in the nailing room, at least one employee, who operated the nailing machine, was not protected from contracting the in-going nip-point created between the drive chain.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 4, 2013
Abate by
Jan 10, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.334(2)(ii) The employer did not ensure that defected or evidence of damaged that exposed an employee to injury ,the defective and damaged item shall be removed from service, and that no employee should use it until repairs and test necessary to render the equipment safe had been made.    This violation most recently occurred on August 14, 2012, in the nailing room, where the employer did not ensure that employees using, 120V-15A-7  circular saw cord that had worn and frayed electrical cord, exposing bare electrical conductors.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500