Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROOF MANAGEMENT INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROOF MANAGEMENT INC. in 1-9 CAPTOLENE AVENUE, BLOOMINGDALE, NJ 07403 (NAICS 238160). OSHA activity number 335850616.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roof Management INC. — free Get an email when a new federal OSHA severe-injury report for Roof Management INC. is published. One employer, no account, unsubscribe in one click.
Site address
1-9 CAPTOLENE AVENUE
City
BLOOMINGDALE
State
NJ
ZIP
07403
Mailing
615 WAYSIDE ROAD, NEPTUNE, NJ 07754
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 3 instances 5 exposed
Issued
Feb 4, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.      a)  Roof of Classroom Building, Front Side, Samuel Donald School:  Employees engaged in the installation of a roof surface did not have acceptable means of fall protection; thereby, were exposed to a fall hazard approximated to be 35' above ground surface below, on or about 8/20/2012.    b) Roof of Classroom Building, Side of Building, Samuel Donald School:  Employees engaged in the installation of a roof surface did not have acceptable means of fall protection; thereby, were exposed to a fall hazard approximated to be 35' above ground surface below, on or about 8/20/2012.    c)  Roof of Gymnasium, Samuel Donald School:  Employees engaged in the installation of a roof surface did not have acceptable means of fall protection; thereby, were exposed to a fall hazard approximated to be 15' above a lower roof surface, on or about 8/20/2012.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 4, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.1053(b)(1):   Where a portable ladder was used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed.    a)  Side of Classroom Building, Samuel Donald School:  Employees used a 40' Werner aluminum extension ladder to access school roof surface.  Ladder rails extended approximately 6" above upper landing surface, on or above 8/20/2012.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View Roof Management INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335850616.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.