Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIMAR STUCCO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIMAR STUCCO, INC. in 825 WEST BRANDON BLVD, BRANDON, FL 33511 (NAICS 238140). OSHA activity number 335864583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vimar Stucco, INC. — free Get an email when a new federal OSHA severe-injury report for Vimar Stucco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VIMAR STUCCO, INC.
Site address
825 WEST BRANDON BLVD
City
BRANDON
State
FL
ZIP
33511
Mailing
1817 PRINCETON LAKES DR. 810, BRANDON, FL 33511
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

9 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.1200(e)(1):     Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     a. South scaffold - the employer did not have a written hazard communication program when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $1200

1910.1200 G01

Serious Gravity 1 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1):     Employers did not have a material safety data sheet in the workplace for each hazardous chemical which they use:    a. South scaffold - the employer did not have material safety data sheets when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $0

1910.1200 H

Serious Gravity 1 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h):     Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced:    a. South scaffold - the employer did not have hazard communication training when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 1 3 exposed
Issued
Sep 20, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:    a. South scaffold - during masonry operations, employee(s) were exposed to a 14' fall hazard, in that, crossbraces were used as a means for access on to the scaffold and a ladder was not used.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $1200

1926.451 G04 I

Serious Gravity 1 3 exposed
Issued
Sep 20, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.451(g)(4)(i):     Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:    a. South scaffold - on a Safway tubular welded frame scaffold, cross bracing sections were used on open sides as toprails and midrails were not used during masonry operations and exposed employee(s) to a 14' fall hazard.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $1200

1926.454 A

Serious Gravity 1 7 exposed
Issued
Sep 20, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.454(a):     The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a. South scaffold - training was not provided to employee(s) prior to masonry operations on a Safway tubular and welded frame scaffold and were exposed to a 14' fall hazard.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (S) $1200

1910.134 C01

Other-than-serious 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1):       The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable:      a. South scaffold - the employer did not have a respiratory protection program when employee(s) were required to use 3M N95 8210 respirator during masonry operations.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (O) $0

1910.134 E01

Other-than-serious 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):       The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:      a. South scaffold - employee(s) required to use 3M 8210 respirator during masonry operations did not have a medical evaluation.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (O) $0

1910.134 F01

Other-than-serious 7 exposed
Issued
Sep 20, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1):       The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):       a. South scaffold - employees required to use N95 3M 8210 respirator during masonry operations did not have fit tests.  Violation observed on or about 8/21/12.
Recent events (1)
  • — Z (O) $0

View Vimar Stucco, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335864583.