BRANDON, FL —
OSHA Inspection: VIMAR STUCCO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIMAR STUCCO, INC. in 825 WEST BRANDON BLVD, BRANDON, FL 33511 (NAICS 238140). OSHA activity number 335864583.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIMAR STUCCO, INC.
- Site address
- 825 WEST BRANDON BLVD
- City
- BRANDON
- State
- FL
- ZIP
- 33511
- Mailing
- 1817 PRINCETON LAKES DR. 810, BRANDON, FL 33511
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.1200 E01
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a. South scaffold - the employer did not have a written hazard communication program when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $1200
1910.1200 G01
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a material safety data sheet in the workplace for each hazardous chemical which they use: a. South scaffold - the employer did not have material safety data sheets when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $0
1910.1200 H
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced: a. South scaffold - the employer did not have hazard communication training when materials such as, but not limited to Florida Super Stucco and sand were used during masonry operations. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Sep 20, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. South scaffold - during masonry operations, employee(s) were exposed to a 14' fall hazard, in that, crossbraces were used as a means for access on to the scaffold and a ladder was not used. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $1200
1926.451 G04 I
- Issued
- Sep 20, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a. South scaffold - on a Safway tubular welded frame scaffold, cross bracing sections were used on open sides as toprails and midrails were not used during masonry operations and exposed employee(s) to a 14' fall hazard. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $1200
1926.454 A
- Issued
- Sep 20, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. South scaffold - training was not provided to employee(s) prior to masonry operations on a Safway tubular and welded frame scaffold and were exposed to a 14' fall hazard. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (S) $1200
1910.134 C01
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable: a. South scaffold - the employer did not have a respiratory protection program when employee(s) were required to use 3M N95 8210 respirator during masonry operations. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (O) $0
1910.134 E01
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. South scaffold - employee(s) required to use 3M 8210 respirator during masonry operations did not have a medical evaluation. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (O) $0
1910.134 F01
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. South scaffold - employees required to use N95 3M 8210 respirator during masonry operations did not have fit tests. Violation observed on or about 8/21/12.
Recent events (1)
- — Z (O) $0
More inspections at Vimar Stucco, INC.
View Vimar Stucco, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335864583.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.