CHICAGO, IL —
OSHA Inspection: GOMEZ TRANSMISSIONS INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of GOMEZ TRANSMISSIONS INC. in 4600 W. CHICAGO AVENUE, CHICAGO, IL 60651 (NAICS 562920). OSHA activity number 335872198.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOMEZ TRANSMISSIONS INC.
- Site address
- 4600 W. CHICAGO AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60651
- Mailing
- 4600 W. CHICAGO AVENUE, CHICAGO, IL 60651
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 55
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 30, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees Entire Facility - On or about August 21, 2012, employees worked at 10 foot heights from a pallet which was supported by the forks of a Hyster powered industrial truck, to install new light fixtures. The employer failed to establish adequate procedures, thereby employees were exposed to falls of ten (10) feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.36 D01
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. Throughout Facility - On or about August 21, 2012, the employer did not provide employees with an exit route door that remained unlocked, thereby exposing employees to smoke inhalation and burns.
Recent events (2)
- — I (O) $0
- — Z (S) $2100
1910.37 A03
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. Throughout facility - On or about August 21, 2012, exits routes were not continuously maintained free of recycled parts, motors and transmissions, thereby exposing employees to obstructed means of egress in the event of an emergency.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1910.37 B06
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 foot lamberts (0.21 cd/m2) are permitted. Throughout facility - On or about August 21, 2012, the emergency exit sign was not illuminated by a reliable light source, thereby exposing employees to burns and smoke inhalation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 E04 III
- Issued
- Oct 30, 2012
- Abate by
- Nov 6, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer. Throughout facility - On or about August 21, 2012, the LP gas cylinder was not securely mounted on the Mitsubishi and Hyster forklift trucks, in that the mounting latches were damaged or missing, thereby exposing employees to struck by, fire, and/or explosion hazards.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.178 M10
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.178(m)(10): A load backrest extension shall be used whenever necessary to minimize the possibility of the load or part of it from falling rearward. Throughout Facility - On or about August 21, 2012, the backrest extension on the Hyster lift trucks were not installed, thereby exposing employees to the hazard of falling material.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.178 Q07
- Issued
- Oct 30, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. Throughout Facility - On or about August 21, 2012, the employer did not perform an examination of the power industrial trucks to check for defects, thereby exposing employee's to serious struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a. Processing - On or about August 21, 2012, the employer failed to guard blades on the cable stripper, thereby exposing employees to the point of operation. b. Processing - On or about August 21, 2012, the employer failed to guard the alligator shear, thereby exposing employees to the point of operation.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.305 G01 IV A
- Issued
- Oct 30, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $2,800 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cable may not be used: As a substitute for the fixed wiring of a structure; Throughout Facility - On or about August 21, 2012, flexible cords were used as a substitute for fixed wiring of a structure for hand held tools, grinders, and other operating equipment, thereby exposing employees to electrical fire hazards.
Recent events (2)
- — I (S) $1700
- — Z (S) $2800
1904.29 A
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $1,000 · Current $0 Reduced
General-duty citation text
29 CFR 1904.29(a): Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report. Recordkeeping - On or about August 21, 2012, the employer did not keep OSHA logs, OSHA summaries or OSHA 300a forms for the last three years.
Recent events (2)
- — I (O) $0
- — Z (O) $1000
More inspections at Gomez Transmissions INC.
View Gomez Transmissions INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335872198.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.