BARRIGADA, GU —
OSHA Inspection: JK TILE STORE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JK TILE STORE in 1090 ROUTE 16, BARRIGADA, GU 96913 (NAICS 423320). OSHA activity number 335874707.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JK TILE STORE
- Site address
- 1090 ROUTE 16
- City
- BARRIGADA
- State
- GU
- ZIP
- 96913
- Mailing
- 1090 ROUTE 16, BARRIGADA, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423320
- Employees
- 29
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.26 C02 VII
- Issued
- Nov 27, 2012
- Penalty
- Initial $3,570 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(vii): 1910.26(c)(2)(7): Ladders having defects were not marked and taken out of service until repaired. Two aluminum step ladders were very damaged and never taken out of service.
Recent events (2)
- — I (S) $1785
- — Z (S) $3570
1910.157 C01
- Issued
- Nov 27, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) A fire extinguisher in the warehouse#1 at the roll-up door was not mounted. b) A fire extinguisher located near the exit door was not mounted. c) A fire extinguisher, located in the warehouse by the emergency exit door was blocked.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.37 B01
- Issued
- Nov 27, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route. The emergency exit sign and emergency lighting leading out of Warehouse #3 was not maintained in working condition that would allow an employee to see their exit route.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.243 C03
- Issued
- Nov 27, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel A small Dewalt brand portable tile grinder was being used with its safety guard missing.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.304 A02
- Issued
- Nov 27, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: A small refrigerator was plugged into a wall outlet that was wired with reverse polarity.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.304 B03 II A
- Issued
- Nov 27, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel. A Dewalt portable grinder was plugged into an extension cord box with no ground-fault circuit-interrupter protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02
- Issued
- Nov 27, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Several outlet boxes did not have covers or faceplates installed. All outlets were energized. a) Warehouse #1 South wall. Duct tape was used to cover an energized outlet that was missing a faceplate. b) Warehouse #1 Southeast wall. A portable power tool was also in use in this outlet that was missing a faceplate. c) Warehouse #1 Near roll-up door a radio was plugged into an energized outlet that was missing a faceplate. d) Warehouse #6 Near the emergency exit door was an energized outlet missing a faceplate. e) Warehouse #7 Near roll-up door an energized outlet was missing a faceplate. f) Warehouse #7 Wall outlet next to emergency lighting was missing a faceplate. g) Warehouse #5 Outlet box next to the rollup door was missing a faceplate.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.334 A02 I
- Issued
- Nov 27, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): The cord of a portable miter saw had not been inspected prior to its use and the ground pin was broken (missing).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections at JK Tile Store
View JK Tile Store's full OSHA safety record →
More inspections in this industry (NAICS 423320)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335874707.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.