OSHA Inspection: JK TILE STORE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JK TILE STORE in 1090 ROUTE 16, BARRIGADA, GU 96913 (NAICS 423320). OSHA activity number 335874707.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JK Tile Store — free Get an email when a new federal OSHA severe-injury report for JK Tile Store is published. One employer, no account, unsubscribe in one click.
Establishment
JK TILE STORE
Site address
1090 ROUTE 16
City
BARRIGADA
State
GU
ZIP
96913
Mailing
1090 ROUTE 16, BARRIGADA, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
29
Ownership type
A

8 citations on file for this inspection.

1910.26 C02 VII

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 27, 2012
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1910.26(c)(2)(vii): 1910.26(c)(2)(7): Ladders having defects were not marked and taken out of service until repaired.    Two aluminum step ladders were very damaged and never taken out of service.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1910.157 C01

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 21, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) A fire extinguisher in the warehouse#1 at the roll-up door was not mounted.  b) A fire extinguisher located near the exit door was not mounted.  c) A fire extinguisher, located in the warehouse by the emergency exit door was blocked.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.37 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 21, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route.      The emergency exit sign and emergency lighting leading out of Warehouse #3 was not maintained in working condition that would allow an employee to see their exit route.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.243 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 21, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel    A small Dewalt brand portable tile grinder was being used with its safety guard missing.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.304 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 21, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity:    A small refrigerator was plugged into a wall outlet that was wired with reverse polarity.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.304 B03 II A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2012
Abate by
Dec 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel.    A Dewalt portable grinder was plugged into an extension cord box with no ground-fault circuit-interrupter protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02

Serious Gravity 5 7 instances 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 7, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:      Several outlet boxes did not have covers or faceplates installed. All outlets were energized.    a) Warehouse #1 South wall. Duct tape was used to cover an energized outlet that was missing a faceplate.  b) Warehouse #1 Southeast wall. A portable power tool was also in use in this outlet that was missing a faceplate.  c) Warehouse #1 Near roll-up door a radio was plugged into an energized outlet that was missing a faceplate.  d) Warehouse #6 Near the emergency exit door was an energized outlet missing a faceplate.  e) Warehouse #7 Near roll-up door an energized outlet was missing a faceplate.  f) Warehouse #7 Wall outlet next to emergency lighting was missing a faceplate.  g) Warehouse #5 Outlet box next to the rollup door was missing a faceplate.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2012
Abate by
Dec 7, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    The cord of a portable miter saw had not been inspected prior to its use and the ground pin was broken (missing).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View JK Tile Store's full OSHA safety record →