OSHA Inspection: F.Q. GUERRERO & ASSOCIATES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of F.Q. GUERRERO & ASSOCIATES in KITCHEN RENOVATION PROJECT AT HERMAN'S BAKERY TUN HERMAN PAN ROAD, VILLAGE OF DAGU, SAIPAN, MP 96950 (NAICS 238340). OSHA activity number 335924288.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F.Q. Guerrero & Associates — free Get an email when a new federal OSHA severe-injury report for F.Q. Guerrero & Associates is published. One employer, no account, unsubscribe in one click.
Site address
KITCHEN RENOVATION PROJECT AT HERMAN'S BAKERY TUN HERMAN PAN ROAD, VILLAGE OF DAGU
City
SAIPAN
State
MP
ZIP
96950
Mailing
PO BOX 500583 CHALAN KANOA, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238340
Employees
11
Ownership type
A

9 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $867 · Current $867
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    Near the south side of the kitchens exterior: On or about August 27, 2012, the metal electrical box, that contained the switch for the 110 VAC tile water saw, was not installed as designed to be installed.  The box was suspended by an electrical cord instead of being mounted to a surface.
Recent events (1)
  • — Z (S) $867

1926.403 I02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more was not guarded against accidental contact by cabinets or other forms of enclosures:    Near the south side of the kitchens exterior: On or about August 27, 2012, there was no enclosure to protect the electrical wires and splices from the switch to the motor on the 110 VAC tile water saw.  The top of the wires and splices was about 19 inches above the ground
Recent events (1)
  • — Z (S) $0

1926.404 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(a)(2): No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity:    Near the south side of the kitchens exterior: On or about August 27, 2012, there was reverse polarity on the electrical outlet that supplied power to a 110 VAC tile water saw.
Recent events (1)
  • — Z (S) $0

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:    Near the south side of the kitchens exterior: On or about August 27, 2012, there was no grounding pin on the plug that supplied power to a 110 VAC tile water saw.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used:    Near the south side of the kitchens exterior: On or about August 27, 2012, the cord that supplied power to a 110 VAC tile water saw was frayed.
Recent events (1)
  • — Z (S) $0

1926.307 C04 I

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $867 · Current $867
29 CFR 1926.307(c)(4)(i) : Projecting shaft ends did not present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves:    Near the south side of the kitchens exterior: On or about August 27, 2012, there was no guard for the  inch diameter shaft that projected about 2 inches from the pulley on the 110 VAC tile water saw.  The top of the pulley was located about 19 inches above the ground.
Recent events (1)
  • — Z (S) $867

1926.307 D01

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.307(d)(1): Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:     Near the south side of the kitchens exterior: On or about August 27, 2012, the  inch V belt and pulley were not guarded on the 110 VAC tile water saw.  The top of the pulley was located about 19 inches above the ground.
Recent events (1)
  • — Z (S) $0

1926.307 E03 I

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.307(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section:    Near the south side of the kitchens exterior: On or about August 27, 2012, the  inch V belt and pulley were not guarded on the 110 VAC tile water saw.  The top of the pulley was located about 19 inches above the ground.
Recent events (1)
  • — Z (S) $0

1926.451 E01

Other-than-serious 1 instance 1 exposed
Issued
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used:    In the kitchen: On or about August 27, 2012, there was no safe access to a scaffold platform that was about 4 feet high.  Employees climbed onto the scaffold and jumped off.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335924288.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.