TROY, TX —
OSHA Inspection: C & H DIE CASTING, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C & H DIE CASTING, INC in 222 LELY ST. (N IH-35 LELY BUSINESS PARK), TROY, TX 76579 (NAICS 331521). OSHA activity number 335958187.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C & H DIE CASTING, INC
- Site address
- 222 LELY ST. (N IH-35 LELY BUSINESS PARK)
- City
- TROY
- State
- TX
- ZIP
- 76579
- Mailing
- P.O. BOX 1170, TROY, TX 76579
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331521
- Employees
- 203
- Ownership type
- A
Citations
27 citations on file for this inspection.
1910.22 A02
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: On or about August 24, 2012, the employer did not ensure that passageways and aisles in the die cast department were kept clean and in a dry condition in that die release agent and hydraulic fluid were present on the floors throughout the die cast department, exposing employee to the hazard of slips, trips and falls.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.23 A08
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded: On or about August 24, 2012, the employer did not ensure that floor holes around the Die Cast Machines in the Die Cast Department were covered, exposing employees to trip hazards.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.24 B
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: On or about August 24, 2012, the employer did not ensure that employees were provided with a fixed staircase to access the top of the die cast machines to change dies. Employees were required to climb onto the machine to gain access to the top, exposing employees to the hazard of falling off the die cast machines at a height up to 8 feet.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.132 A
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about August 24, 2012, the employer did not ensure that employees were provided with fall protection while setting dies into the top of the die cast machines located in the die cast department, exposing employees to the hazard of falls of more than eight feet.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.147 C04 I
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 24, 2012, the employer did not ensure that the energy control procedures for the Mazak CNC machine were utilized before allowing employees to enter the machine to perform work, exposing employees to the hazard of being caught in the machine.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.147 C06 I
- Issued
- Feb 22, 2013
- Abate by
- May 15, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about August 24, 2012, a periodic evaluation of the energy control procedure was not performed for equipment such as, but not limited to, Die Cast Machines. The last certification of evaluation of the procedure was dated March 28, 2009.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.157 C01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about August 24, 2012, the employer did not ensure that portable fire extinguishers were made readily available for employee use in three instances; a) In the Die Cast machine Department on a column next to the DCM# 22 the fire extinguisher was missing and not mounted in its designated location. b) In the Die Casting Machine Department in the southwest corner on the wall the fire extinguisher was missing and not mounted in its designated location. c) In the Furnace Department on the southeast corner of the building the fire extinguisher was missing and not mounted in its designated location.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.157 G01
- Issued
- Feb 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting: On or about August 24, 2012, the employer did not ensure that employees working in the facility were trained on the principles of fire extinguisher use and the hazards involved with incipient stage fires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q06
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.178(q)(6): Industrial trucks were altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts. On or about August 24, 2012, the employer replaced the seat of the Toyota Forklift with a tractor seat that did not have a seatbelt.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.184 E01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that all of the alloy steel chains used in the facility had identification tags that were legible and installed on the slings, exposing employees to being crushed by falling loads in the event of overloading the chain.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.212 A01
- Issued
- Feb 22, 2013
- Abate by
- May 15, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about August 24, 2012, and at times prior thereto, the employer did not provide machine guards in three different areas and a total of 12 instances within the facility, exposing the employee to the hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) In the Die Cast Machine Department on DCM #23 there was a wire mesh guard cover removed along the backside of the machine. The guard was located on the floor next to the machine. b) In the Die Cast Machine Department next to DCM #24 there was a 10 foot conveyor belt that did not have guards installed over the edges of the belt. c) In the High Procession Area on the Mazak FH 580 CNC Machine had the access door on the rear of the machine opened and the interlock had been by-passed. d) In the High Procession Area there were 7 Jorgensen Chip Conveyor belts that were missing guard covers over the ends of the ejection area. e) In the secondary work department on the Burr King Model 482 Three Wheel Grinder was missing a guard over the sanding belt. f) In the High Procession Area on the #301 Mazak CNC machine Model #FH 580, interlocked barrier guards were removed. g) In the High Procession Area on the #302 Mazak CNC machine Model #FH 580, interlocked barrier guards were removed. h) In the High Procession Area on the #303 Mazak CNC machine Model #FH 580, interlocked barrier guards were removed. i) In the High Procession Area on the #304 Mazak CNC machine Model #FH 580, interlocked barrier guard removed. j) In the High Procession Area on the #305 Mazak CNC machine Model #FH 580, interlocks had been by-passed. k) In the High Procession Area on the #321 Mazak CNC machine Model #FH 580, interlock barrier guards were removed. l) In the High Procession Area on the #323 Brother CNC Machine Model # TC-324 had the interlock on the doors by-passed.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.213 I01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded. On or about August 24, 2012, and at times prior thereto, the Work-A-Matic Bandsaw located in the Die Cast Repair department did not have guards installed over the non-working portion of the blade.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.215 A04
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch. On or about August 24, 2012, and at times prior thereto, the employer did not ensure that the work rests on the Jet 8 inch bench grinder were adjusted properly. The work rests were over one inch from the wheels, exposing employees to the hazards of being caught in the wheel or struck by wheel fragments.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.215 B09
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about August 24, 2012, and at times prior thereto, the Jet 8 inch bench grinder was used with the adjustable tongue guards approximately one and one quarter inches from the grinding wheel periphery, exposing employees to the hazard of being struck by flying wheel fragments in the event of wheel breakage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about August 24, 2012, and at times prior thereto, the belt and pulleys on the Burr King Three Wheel Grinder were not guarded, exposing employees to the hazards of being caught in belt/pulley pinch points.
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.219 E01 I
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about August 24, 2012, and at times prior thereto, the belt and pulleys on the Burr King Three Wheel Grinder were not guarded, exposing employees to the hazards of being caught in belt/pulley pinch points.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about August 24, 2012, and at times prior thereto, air nozzles were routinely used for cleaning at compressed air pressures up to 60 psig, exposing employees to the hazards of being struck by shavings and/ or high pressure air.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.303 B07 IV
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a) On or about August 24, 2012, the power control handle was broken and missing on the power control panel for Die Cast Machine #20, exposing employees to the hazard of electrical shock. b) On or about August 24, 2012, the reset switches for the fans in the Die casting and the Furnace departments were broken and recessed into the control panels, requiring that the employees put their fingers into the power panels to reach the switches.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.305 E01
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that the oil heater cabinet in the die cast department was installed to prevent moisture from entering the cabinet, exposing employees to the hazards of electrical shock and fire.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.303 G02 I
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about August 24, 2012, and at times prior thereto the employer did not ensure that electrical equipment operating at 50 volts or more was guarded against accidental contact by approved cabinets or other approved enclosures in 2 instances, exposing employees operating the equipment to electrical hazards. a) In the Die Cast Department the Mokon 460 Volt Die heater had an access door to the live parts. It was not kept locked or otherwise secured from unqualified employees accessing the live parts. b) In the Die Cast Department the 110 volt power control panel for Trim Press # 24 had a hole cut into the side of the box, exposing employees to live parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 X
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that the flexible cord on the Work-A-Matic band saw was protected from accidental damage by the rough edges of the bandsaw table.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.305 B01 I
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that conductors entering cutout boxes, cabinets, or fittings were protected from abrasions in two instances: a) On the back of DCM #26 a bundle of red electrical wires was entering a junction box and the fittings were not installed to prevent them from abrasions. b) On the back of DCM #22 on the white junction box the fittings were not connected as to prevent abrasion to the wires.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.305 B01 II
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that unused openings in a 220 Volt receptacle box located in the furnace department were effectively closed.
Recent events (2)
- — I (S) $2520
- — Z (S) $3600
1910.305 B02 I
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $5,400 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that pull boxes, junction boxes, and fittings were provided with covers in four instances, exposing employees to the hazard of electrical shock. a) In the Die Cast Department on the DCM #24 the butterfly valve junction box cover was missing. b) In the Die Cast Department on the DCM #24 the junction box cover for the furnace blower motor was missing. c) In the Die Cast Department on DCM #23 the junction box cover for the furnace blower motor as missing. d) In the Die Cast Department on DCM #23 the butterfly valve junction box cover was missing.
Recent events (2)
- — I (S) $3780
- — Z (S) $5400
1910.305 G01 III
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not equipped with an attachment plug and energized from an approved receptacle outlet: On or about August 24, 2012, and at times prior thereto, the employer did not ensure that the yellow flexible wire connection for the vacuum system for Die Cast Machine #19 was installed with an attachment plug.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.305 G02 II
- Issued
- Feb 22, 2013
- Abate by
- May 15, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap: On or about August, 24, 2012, and at times prior thereto, the employer did not ensure that flexible cords were used in continuous lengths without splice or tap in two instances, exposing employees to the hazards of electrical shock. a) In the Die Cast Department four Shot Monitoring Boxes that were installed and power supply cords had wire nut splices in them. b) In the Die Cast Department three Trim Presses were installed and the wires had wire nut splices in them.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.305 G02 III
- Issued
- Feb 22, 2013
- Abate by
- Feb 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about August 24, 2012, and at times prior thereto, flexible cords used in the facility were found with the outer insulation pulled away from the plugs' strain relief in two instances, exposing employees to the hazard of electrical shock. a) In the die cast department a metal Dayton floor fan Model #6K809G was observed with the outer insulation pulled away from the attachment cap. b) In the die repair department the job made fan was observed with the outer insulation pulled away from the connector on the on/off switch box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at C & H DIE Casting, INC
View C & H DIE Casting, INC's full OSHA safety record →
More inspections in this industry (NAICS 331521)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335958187.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.