AKRON, OH —
OSHA Inspection: LANDMARK PLASTICS CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LANDMARK PLASTICS CORPORATION in 1331 KELLY AVE, AKRON, OH 44306 (NAICS 326199). OSHA activity number 335958427.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LANDMARK PLASTICS CORPORATION
- Site address
- 1331 KELLY AVE
- City
- AKRON
- State
- OH
- ZIP
- 44306
- Mailing
- 1331 KELLY AVE, AKRON, OH 44306
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 164
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.26 C02 VII
- Issued
- Feb 12, 2013
- Penalty
- Initial $3,960 · Current $2,960 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects are to be marked and taken out of service until repaired by either maintenance department or the manufacturer: On or before 08/16/2012 the Louisville trestle ladder with severely bent spreaders and a damaged foot tread, was not removed from service.
Recent events (2)
- — I (S) $2960
- — Z (S) $3960
1910.27 B01 II
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $2,970 · Current $0 Reduced
General-duty citation text
29 CFR 1910.27(b)(1)(ii): The distance between rungs, cleats, and steps shall not exceed 12 inches and shall be uniform throughout the length of the ladder: The steps of the fixed ladder on thermo-former press, located in the Trim press area, line #11 were not uniform. The distance of the bottom step measured approximately 27 inches, from ground level to the first step.
Recent events (2)
- — I (S) $0
- — Z (S) $2970
1910.147 C05 I
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $4,950 · Current $3,465 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: On and before 08/16/2012 the main electrical disconnect for the Husky (horizontal) injection mold machine, was not secured by a lock or other device. Employee(s) tasked with changing out hydraulic hoses on the machinery were exposed to hazards created by, unexpected engagement or start-up of the machinery.
Recent events (2)
- — I (S) $3465
- — Z (S) $4950
1910.147 C06 I
- Issued
- Feb 12, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $4,950 · Current $3,465 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: As of 08/16/2012 annual inspections or audits of the company's lockout procedures were not completed, as required. Employees completing lock out at the site were not provided locks, tags, or other hardware to isolate, secure or block machinery or equipment from energy sources.
Recent events (2)
- — I (S) $3465
- — Z (S) $4950
1910.184 D
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $3,960 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer: On and before 08/16/2012 various slings (web, chain, etc.) utilized at the facility were not inspected daily prior to being placed into service.
Recent events (2)
- — I (S) $0
- — Z (S) $3960
1910.184 I09 III
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $0 · Current $2,770
General-duty citation text
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service: The employer failed to ensure that frayed or snagged web slings, used by employee(s) when hoisting various production material(s) in the shop area, were removed from service and discarded.
Recent events (2)
- — I (S) $2770
- — Z (S) $0
1910.219 F03
- Issued
- Feb 12, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $4,950 · Current $3,460 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: On and before 08/16/2012 the chain and sprocket assembly, on several of the Thermo-former (TFO) units, located in the Trim Press area of the site was not adequately guarded. Equipment includes, but is not limited, the Thermo-former (TFO) machinery in line # 1, line#2, and line # 11.
Recent events (2)
- — I (S) $3460
- — Z (S) $4950
1910.303 B01
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $3,960 · Current $2,960 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: The conduit, which contained the electrical wiring for Thermo-former (TFO) presses (line #7 and #9) located in the Trim Press area of the shop was damaged, thus exposing operator(s) and other employees working in the area to potential electrical hazards.
Recent events (2)
- — I (S) $2960
- — Z (S) $3960
1910.303 B02
- Issued
- Feb 12, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $3,960 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A metal junction box, located in the Trim Press area next to thermo-former line #1, was neither mounted to a fixed surface, nor connected to the conduit.
Recent events (2)
- — I (S) $0
- — Z (S) $3960
More inspections at Landmark Plastics Corporation
View Landmark Plastics Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335958427.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.