Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KROGH-BUILT CABINETRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KROGH-BUILT CABINETRY in 164 MILTON AVENUE, ALPHARETTA, GA 30009 (NAICS 337110). OSHA activity number 335961793.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Krogh-Built Cabinetry — free Get an email when a new federal OSHA severe-injury report for Krogh-Built Cabinetry is published. One employer, no account, unsubscribe in one click.
Site address
164 MILTON AVENUE
City
ALPHARETTA
State
GA
ZIP
30009
Mailing
164 MILTON AVENUE, ALPHARETTA, GA 30009
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.213 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 29, 2012
Abate by
Oct 30, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.213(c)(1): A circular handfed ripsaw/crosscut saw was not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a) Fabrication area. The upper portion of the blade of a sliding table woodworking saw was not guarded.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 29, 2012
Abate by
Oct 30, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Fabrication area. A blow-off nozzle used to remove dirt and debris from material and equipment, as well as the employees clothing, was not equipped with a pressure reducer. The air was being delivered at 90 psi.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

View Krogh-Built Cabinetry's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335961793.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.