BROOKLYN, NY ·
OSHA Inspection: BAYPORT CONSTRUCTION CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BAYPORT CONSTRUCTION CORP in 60 HOYT STREET, BROOKLYN, NY 11201 (NAICS 238140). OSHA activity number 336085584.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAYPORT CONSTRUCTION CORP
- Site address
- 60 HOYT STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11201
- Mailing
- 14B 53RD STREET SUITE 7B, BROOKLYN, NY 11232
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 55
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.20 B02
- Issued
- Dec 31, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite: a) Employer did not inspect and determine that the work floor of the construction site was installed and maintained in accordance with the project design plan and the cement board manufacturers specifications. The floor broke under an employee who fell 10 feet to the basement. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2695
- · Z (S) $5390
1926.25 A
- Issued
- Dec 31, 2012
- Abate by
- Jan 8, 2013
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept cleared from work areas, passageways, and stairs, in and around buildings and other structures: a) Accumulated construction debris on the ground outside the apartment units was causing trip hazard to employees. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1155
- · Z (S) $2310
1926.501 A02
- Issued
- Dec 31, 2012
- Abate by
- Jan 7, 2013
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926. 501(a)(2): The employer shall determine if the walking/working surfaces on which its employees are to work have the strength and structural integrity to support employees safely. Employees shall be allowed to work on those surfaces only when the surfaces have the requisite strength and structural integrity: Employees were exposed to floor collapse hazard at the construction site where a inch thick cement board subflooring was being used as the working floor. A section of cement board measuring 2ft by 3ft broke under an employee who then fell 10 feet into the basement. The floor was designed to have inch plywood installed over the cement board but the plywood had not been installed yet so the floor had limited ability to withstand impact loads or point loads. Additionally, the following conditions were observed: a) The joist floor beams underneath the cement board where the floor broke were spaced 26 inches on-center which did not conform to the project design plan which specified 19 inch spacing; the cement board manufacturer specified 24 inch maximum joist spacing. b) The cement board that was used was rated 76 psf (pounds per square foot) load capacity which did not conform to the project design plan which specified USG or equivalent cement board which has 110 lb psf load capacity. c) Sheets of plywood were not placed over the cement board floor in high traffic areas to protect from impact loads, as instructed by the cement board manufacturer (not to be confused with the inch plywood that was to be installed as part of the completed floor). Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2695
- · Z (S) $5390
1926.502 B01
- Issued
- Dec 31, 2012
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of top rails, or equivalent guardrail systems members, was not 42 inches plus or minus three inches above the walking/ working level: a) Employees were exposed to falling 10 ft into the building basement along the driveway at the entrance to the site where there was a guardrail but it was not of adequate height. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1540
- · Z (S) $3080
1926.502 I03
- Issued
- Dec 31, 2012
- Abate by
- Jan 8, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.502(i)(3): All floor hole covers were not secured when installed so as to prevent accidental displacement by wind, equipment, or employees: a) The employer placed loose (unsecured) pieces of plywood to cover where there were holes in the cement board floors. Employees were exposed to floor hole hazard if the plywood covers move during construction activities. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
1926.502 I04
- Issued
- Dec 31, 2012
- Abate by
- Jan 8, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.502(i)(4): All floor hole covers were not color coded or marked with the word HOLE or COVER to provide warning of the hazard: a) The employer placed pieces of particle board over where there were holes in the cement board floors. The covers were not marked "FLOOR HOLE". The covers were made of 3/8 to 1/2 inch thick particle board and can break if overloaded by heavy construction materials or equipment such as ciinderblocks and pipe frame scaffolds that were being used at the jobsite. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
1926.503 A01
- Issued
- Dec 31, 2012
- Abate by
- Jan 9, 2013
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. Training is to include the fall protection training requirements listed in (a)(2)(i) through (2)(viii) including; fall hazards, fall protection procedures, use and limitations of fall protection systems, role of employees: a) The employer did not train employees on safe installation requirements for cement board sub-flooring; including but not limited to: covering the high traffic areas with loose sheets of plywood to protect from point and impact loads; and keeping the floor joists spaced 19 inches on-center. Location: 60 Hoyt St, Brooklyn N.Y. On or about 7/31/2012 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
More inspections at Bayport Construction Corp
View Bayport Construction Corp's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 336085584.