Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOLAR SOLUTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLAR SOLUTION LLC in 3000 12TH ST NE, WASHINGTON, DC 20017 (NAICS 238990). OSHA activity number 336099429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solar Solution LLC — free Get an email when a new federal OSHA severe-injury report for Solar Solution LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SOLAR SOLUTION LLC
Site address
3000 12TH ST NE
City
WASHINGTON
State
DC
ZIP
20017
Mailing
4700 14TH ST NW, WASHINGTON, DC 20011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2012
Abate by
Dec 4, 2012
Penalty
Initial $4,000 · Current $3,500 Reduced
29 CFR 1926.501(b)(10):     "Roofing work on Low-slope roofs." Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.     a) Front Center of Roof - Worker observed standing on top of the parapet wall that surrounded a roof. The worker was lifting solar panels by hand, from the ground. The worker was not protected from falling, by any of the required systems, 30 feet to the concrete surface below, on 08/30/2012.    Solar Solution was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(1) which was contained in OSHA inspection number 315456442, citation number 1, item number 2 and was affirmed as a final order on May 27, 2011, with respect to a workplace located at 1313 Constitution Ave NE, Washington, DC 20002.
Recent events (2)
  • — I (R) $3500
  • — Z (R) $4000

1926.1053 B01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 28, 2012
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access;     a) Front Center of Structure - Worker observed using ladder to gain access to roof. The ladder extended approximately 24 inches above landing surface on 08/30/2012.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2200