OSHA Inspection: SOLAR SOLUTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLAR SOLUTION LLC in 3727 BRANDYWINE RD NW, WASHINGTON, DC 20007 (NAICS 221114). OSHA activity number 339790859.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solar Solution LLC — free Get an email when a new federal OSHA severe-injury report for Solar Solution LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SOLAR SOLUTION LLC
Site address
3727 BRANDYWINE RD NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
4700 14TH STREET NW, WASHINGTON, DC 20001
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 9, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On May 19, 2014 and at times prior thereto; roof area; the ladder used to access the work area was set flush to the working platform exposing them to a fall hazard of 25 feet to ground level while accessing or stepping off the ladder to the platform.
Recent events (1)
  • — Z (S) $2000

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 9, 2014
Penalty
Initial $5,600 · Current $5,600
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On May 19, 2014 and at times prior thereto; roof area, employees were observed working on a 4:12 pitch roof of a two story residential home without a personal fall arrest system in place to prevent them from falling 20-30 feet to ground level.   The Solar Solution LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 547438, citation number 1, item number 1 and was affirmed as a final order on (date), with respect to a workplace located at 1316 Irving St NW Washington DC.
Recent events (1)
  • — Z (R) $5600

View Solar Solution LLC's full OSHA safety record →