NAMPA, ID ·
OSHA Inspection: WOODGRAIN MILLWORK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOODGRAIN MILLWORK, INC. in 1201 WEST KARCHER ROAD, NAMPA, ID 83687 (NAICS 321918). OSHA activity number 336238589.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WOODGRAIN MILLWORK, INC.
- Site address
- 1201 WEST KARCHER ROAD
- City
- NAMPA
- State
- ID
- ZIP
- 83687
- Mailing
- POST OFFICE BOX 9489, NAMPA, ID 83652
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 1900
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.212 A03 II
- Issued
- Oct 31, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $3,400 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) Maintenance Shop: On 8/7/12 and at times prior thereto, the lathe guard provided did not cover the chuck area during operation. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $2400
- · Z (S) $3400
1910.22 A02
- Issued
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floors of every workroom were not maintained in a clean condition: (a) Near Glue/Lam: On 8/7/12 and at times prior thereto, dust and wood chips were allowed to build up in an area approximately 15 feet by 15 feet. Note: Abatement certification IS NOT required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.36 F02
- Issued
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(f)(2): The capacity of an exit route decreased in the direction of exit route travel to the exit discharge: (a) Excess equipment storage: on 8/7/12 and at times prior thereto, the exit route from an electrical service panel was narrowed by improper storage on tools and equipment. NOTE: Abatement certification IS NOT required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.184 I01
- Issued
- Oct 31, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: (a) Maintenance Shop: On 8/7/12 and at times prior thereto, a rack of web slings contained a sling with most of the required ID tag torn away and missing. NOTE: Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 B01 II
- Issued
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Glass Warehouse: on 8/7/12 and at times prior thereto, a missing cap for a metal raceway containing insulated electrical wires enabled foreign materials and rodent entry into live electrical parts. NOTE: Abatement certification IS NOT required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G02 III
- Issued
- Oct 31, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) 1 inch woodworkers shaper: On 8/7/12 and at times prior thereto, the service disconnect wiring clamp was not gripping the cable which allowed direct pull on terminal screws. NOTE: Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Woodgrain Millwork, INC.
View Woodgrain Millwork, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 336238589.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.