PITTSTON, PA —
OSHA Inspection: LETICA CORPORATION
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of LETICA CORPORATION in 2 COMMERCE ROAD, PITTSTON, PA 18641 (NAICS 322219). OSHA activity number 336243183.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LETICA CORPORATION
- Site address
- 2 COMMERCE ROAD
- City
- PITTSTON
- State
- PA
- ZIP
- 18641
- Mailing
- 2 COMMERCE ROAD, PITTSTON, PA 18641
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322219
- Employees
- 92
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 8, 2013
- Abate by
- Apr 24, 2013
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Printing area: The rollers on a 4-color printing machine were not equipped with an in-running nip point guard exposing workers to an amputation hazard, on or about September 12, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.303 B02
- Issued
- Mar 8, 2013
- Abate by
- Mar 20, 2013
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Printing area: A metal receptacle box, approved for fixed installations, was attached to a flexible cord and used for purpose other than that which it was approved exposing workers to an electric shock hazard, on or about September 12, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.305 G01 IV A
- Issued
- Mar 8, 2013
- Abate by
- Mar 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Printing area: An extension cord fitted with a metal receptacle box had been installed in place of permanent wiring to to power a pair of portable fans exposing workers to an electric shock hazard, on or about September 12, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Mar 8, 2013
- Abate by
- Mar 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Printing area: The flexible cord attached to a metal receptacle box was not provided with strain relief exposing workers to an electric shock hazard, on or about September 12, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 II
- Issued
- Mar 8, 2013
- Abate by
- Apr 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Maintenance Area: A maintenance worker who uses an air purifying respirator had not been medically screened to ensure that the use of a respirator does not create a health hazard, on or about September 12, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Letica Corporation
View Letica Corporation's full OSHA safety record →
More inspections in this industry (NAICS 322219)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336243183.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.