SAN DIEGO, CA —
OSHA Inspection: AIR NATIONAL GUARD 147TH COMBAT COMMUNICATIONS SQUADRON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR NATIONAL GUARD 147TH COMBAT COMMUNICATIONS SQUADRON in 7288 CONVOY TERRACE, SAN DIEGO, CA 92111 (NAICS 928110). OSHA activity number 336250188.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 7288 CONVOY TERRACE
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92111
- Mailing
- 7288 CONVOY TERRACE, SAN DIEGO, CA 92111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 26
- Ownership type
- D
Citations
10 citations on file for this inspection.
1910.37 B06
- Issued
- Oct 4, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: In the Eagle Vision mobile shelter - On or about 9/14/12, exit signs were not illuminated.
Recent events (1)
- — Z (S) $0
1910.157 E02
- Issued
- Oct 4, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) In Bldg. 2, Vehicle maintenance shop - On or about 9/11/12, a fire extinguisher was not inspected at least monthly. b) In HAZMAT storage unit 1 - On or about 9/14/12, a fire extinguisher was not inspected at least monthly. c) In HAZMAT storage unit 2 - On or about 9/14/12, a fire extinguisher was not inspected at least monthly. d) In Bldg. 2, Room A102, adjacent to clip board area - On or about 9/14/12, a fire extinguisher was not inspected at least monthly. e) In Bldg. 2, Room A102, adjacent to bay door - On or about 9/14/12, a fire extinguisher was not inspected at least monthly.
Recent events (1)
- — Z (S) $0
1910.165 E
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.165(e): Manually operated actuation devices for use in conjunction with employee alarms were not unobstructed, conspicuous and readily accessible: In Bldg. 1, Warehouse - On or about 9/11/12, a fire alarm manual pull box was obstructed by a ladder stand.
Recent events (1)
- — Z (S) $0
1910.176 C
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage: In Bldg. 1, Room 133 - On or about 9/11/12, weighing scales were stored on the floor posing tripping hazards.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: In Bldg. 2, Vehicle maintenance shop - On or about 9/11/12, a drill press did not have a chip guard installed to prevent injury to employees from flying debris.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) In the Warehouse - On or about 9/4/12, an oxygen cylinder and an acetylene cylinder were stored together on a cart. b) In the Warehouse, storage area - On or about 9/4/12, oxygen and acetylene cylinders were stored together.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Oct 4, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) In Bldg. 2, Vehicle maintenance shop - On or about 9/11/12, equipment was stored in front of two electrical switch boxes. b) In the Eagle Vision mobile shelter - On or about 9/14/12, an electrical panel was blocked by a printer. c) In the Eagle Vision mobile shelter - On or about 9/14/12, an electrical panel was blocked by a large screen television.
Recent events (1)
- — Z (S) $0
1910.305 A02 X
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) In Bldg. 1, Room 133 - On or about 9/11/12, an extension cord was threaded through the ceiling. b) In the Eagle Vision mobile shelter - On or about 9/14/12, an extension cord was threaded through doorways.
Recent events (1)
- — Z (S) $0
1910.305 C04
- Issued
- Oct 4, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: In Bldg. 2, Vehicle maintenance tool room, adjacent to rollup window - On or about 9/14/12, a light switch faceplate did not adequately cover electrical wiring.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Oct 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) In Bldg. 1, Material control office - On or about 9/11/12, an extension cord was used as permanent wiring to supply power to an air conditioner. b) In Bldg. 2, Gym - On or about 9/14/12, an extension cord was used as permanent wiring to supply power to an electric fan.
Recent events (1)
- — Z (S) $0
More inspections at AIR National Guard 147TH Combat Communications Squadron
View AIR National Guard 147TH Combat Communications Squadron's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336250188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.