Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR NATIONAL GUARD 147TH COMBAT COMMUNICATIONS SQUADRON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIR NATIONAL GUARD 147TH COMBAT COMMUNICATIONS SQUADRON in 7288 CONVOY TERRACE, SAN DIEGO, CA 92111 (NAICS 928110). OSHA activity number 344252812.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR National Guard 147TH Combat Communications Squadron — free Get an email when a new federal OSHA severe-injury report for AIR National Guard 147TH Combat Communications Squadron is published. One employer, no account, unsubscribe in one click.
Site address
7288 CONVOY TERRACE
City
SAN DIEGO
State
CA
ZIP
92111
Mailing
7288 CONVOY TERRACE, SAN DIEGO, CA 92111
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
20
Ownership type
D

8 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 12 exposed
Issued
Sep 30, 2019
Abate by
Oct 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  Building 3, Warehouse:  South Side the exit route was obstructed with material and equipment.  Employees were exposed due to the inability to egress because of obstructions to the exit door in an emergency.
Recent events (1)
  • — Z (S) $0

1910.159 C10

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems and the material below was not maintained:  Building 2, Mechanical room: Employees maintain electrical power and back up systems throughout the work area. Inside the Mechanical Room, the sprinkler discharge pattern was obstructed by boxed picture frames stacked below the sprinkler head. Employees were exposed to fire and smoke inhalation hazards.
Recent events (1)
  • — Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  Building 2, Power Pro Garage: The employer has operated a Hyster forklift with a MECO work platform attachment that did not have manufacturer's written approval.  Employees are exposed to fall hazards 6 feet to a lower level.
Recent events (1)
  • — Z (S) $0

1910.178 L03 I G

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 30, 2019
Abate by
Oct 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(3)(i)(G): Powered industrial truck operators did not receive training on attachment adaptation, weight of the attachment, and use limitations;   Building 2, Power Pro Garage: Employees were using a forklift attachment to take photos and change light bulbs without being provided training specific to the work platform attachment. Employees were improperly using a ratchet strap to secure the work platform to the forklift mast. Employees are exposed to falls of 6 feet to a lower level.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 30, 2019
Abate by
Oct 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Building 2, CE shop: The drill press was found in the shop used for drilling metal material items for fabrication did not have a guard on the equipment to protect against flying metals from the point of operation.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 30, 2019
Abate by
Oct 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  Building 2, Mechanical Room: Employees were exposed to electrical shock due to the strain relief (rubber sheathing) being pulled away from the coated electrical copper wire plug housing point. The APC backup power supply unit was found plugged into an 110 Volt electrical outlet.
Recent events (1)
  • — Z (S) $0

1910.334 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 30, 2019
Abate by
Oct 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(1) Flexible electric cord may not be hung in a fashion as could damage the outer jacket or insulation.  Building 2, Eagle Area:  A black power cord was wrapped around the truss, which had sharp edges. Employees were exposed to electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2019
Abate by
Oct 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   Building 3, Warehouse: Two Amerex fire extinguishers were placed on the floor adjacent to drum containers on a pallet and were standing upright not secured. Employees are exposed to fire hazards.
Recent events (1)
  • — Z (O) $0

View AIR National Guard 147TH Combat Communications Squadron's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344252812.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.