LAUREL, MS —
OSHA Inspection: HANCOCK MECHANICAL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HANCOCK MECHANICAL, LLC in 3616 INDUSTRIAL BLVD, LAUREL, MS 39440 (NAICS 332996). OSHA activity number 336402185.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HANCOCK MECHANICAL, LLC
- Site address
- 3616 INDUSTRIAL BLVD
- City
- LAUREL
- State
- MS
- ZIP
- 39440
- Mailing
- 3616 INDUSTRIAL BLVD, LAUREL, MS 39440
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 69
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 1, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a) Facility wide - On or about September 12, 2012, specific procedural steps were not developed and used for specific machines and equipment covered by this section.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.147 C06 II
- Issued
- Oct 1, 2012
- Abate by
- Nov 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the ins (a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) (IDENTIFY MACHINERY OR EQUIPMENT) a) Facility wide - On or about September 12, 2012, periodic inspections were not conducted at least annually to assure that the specific procedure was valid and that it was correctly followed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 H04
- Issued
- Oct 1, 2012
- Abate by
- Oct 23, 2012
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.179(h)(4): Hooks did not meet the manufacturer's recommendations a) Weld shop - On or about September 12, 2012, the overhead 1 ton crane had a defective safety latch.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.179 L03 I
- Issued
- Oct 1, 2012
- Abate by
- Oct 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: a) Weld shop - On or about September 12, 2012, the overhead 1 ton crane had a defective safety latch and was not removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- Oct 1, 2012
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Weld shop next to the tool room - On or about September 12, 2012, the bench mounted grinder had a gap of 1/2 inch between the abrasive wheel and the tool rest.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.215 B09
- Issued
- Oct 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Weld shop next to the tool room - On or about September 12, 2012, the bench mounted grinder had a gap of 7/8 inch between the abrasive wheel and the tongue guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Oct 1, 2012
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Weld shop - On or about September 12, 2012, the circuit breakers in the panels near the office were not fully labeled to indicate its purpose.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.307 C02 I
- Issued
- Oct 1, 2012
- Abate by
- Oct 30, 2012
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the class of location: a) Spray booth - On or about September 12, 2012, the electrical wiring and fixtures in the spray booth was not approved for Class 1 or Class II location.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
More inspections at Hancock Mechanical, LLC
View Hancock Mechanical, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336402185.