MEADVILLE, PA —
OSHA Inspection: TAMARACK PACKAGING LIMITED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TAMARACK PACKAGING LIMITED in 11124 MERCER PIKE, MEADVILLE, PA 16335 (NAICS 326199). OSHA activity number 336468582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAMARACK PACKAGING LIMITED
- Site address
- 11124 MERCER PIKE
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- PO BOX 693, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.106 E09 III
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 employees using the silk screen machines would use EasiSolv cleaner on a disposable cloth to clean screens that are in use. The EasiSolv cloths would be disposed of in a cardboard box along with other trash.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.147 C04 II
- Issued
- Feb 25, 2013
- Abate by
- Apr 23, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec. a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 the control of hazardous energy procedures (lockout/tagout) did not list all steps for shutting down and securing machines and the placement, removal or transfer of lockout/tagout devices and how to verify lockout/tagout was successful for machines as well as annual audits of the lockout/tagout procedure. Machines that would need lockout/tagout include, but are not limited to, the die cutting machine, Thermoformer #94, Termoformer #85 and the Kbar Sealers.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.212 A01
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 employees were not protected from caught between injuries on the Armac Thermoformer #94 between a stationary blue support of the machine and the stationary red housing in which the plastic moves through and the top of the piston that has a metal support for the stacking portion of the machine.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.303 B07 I
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 there were missing electrical blanks in the electrical panel box labeled 120/208 volt press control power panel, fed from mezz panel SDPH, Breaker #7 Panel I near the ink storage cabinets.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.303 B01 II
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 gauze and tape were used instead of knockouts in electrical panel box labeled 120/208 volt press control power panel, fed from mezz panel SDPH, Breaker #7 Panel I near the ink storage cabinets.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 a light table plug located near the sewing machines and near the silk screen cleaning area was damaged. The outer jacket pulled away from the plug end exposing electrical wires. b) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 the outer jacket of an electrical cord going to an outlet box on a table next the Thermoformer #85 was pulled away from the wires at the outlet box.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.178 A05
- Issued
- Feb 25, 2013
- Abate by
- Mar 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. a) Tamarack Packaging Limited / 11124 Mercer Pike, Meadville, PA: On or about September 20, 2012 the company periodically uses a forklift with a man lift attachment. The forklift data plate did contain information about use of the man lift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Tamarack Packaging Limited